Related Experiment Video
Updated: Jul 13, 2026

07:16
Finite Element Analysis Model for Assessing Expansion Patterns from Surgically Assisted Rapid Palatal Expansion
Published on: October 20, 2023
Tilting of splinted implants for improved prosthodontic support: a two-dimensional finite element analysis
Antonios Zampelis1, Bo Rangert, Lars Heijl
1Postgraduate Program in Periodontics, Goteborg University, Goteborg, Sweden. odoanz@odontologi.gu.se
The Journal of Prosthetic Dentistry
|April 30, 2008
Summary
Tilting distal implants for fixed restorations does not increase bone stress. This technique offers a biomechanical advantage over distal cantilevers in dental implantology.
Area of Science:
- Dental Implantology
- Biomechanics
- Finite Element Analysis
Background:
- Maxillary sinus and mental foramen presence can limit posterior dental implant placement.
- Tilting distal implants is a potential alternative for fixed restorations.
Purpose of the Study:
- Evaluate stress distribution in bone surrounding tilted splinted implants.
- Compare biomechanical superiority of tilted distal implants versus distal cantilevers.
Main Methods:
- Developed a 2-D finite element analysis model with two splinted implants.
- Simulated bone properties and physiologic bone remodeling.
- Compared tilted implants (45 degrees) to a distal cantilever model.
Main Results:
- Implant tilting did not increase stress at the bone-implant contact.
- Cantilevers resulted in higher marginal bone stress.
- Tilted distal implants reduced stress compared to cantilevers.
Conclusions:
- Distal tilting of splinted implants does not elevate bone stress.
- Tilted distal implants are biomechanically advantageous over distal cantilevers.