Related Experiment Video
Updated: Jul 13, 2026

Implantation Protocol of the Foldable Capsular Vitreous Body for Complex Vitreoretinal Surgery
Published on: April 14, 2026
25-gauge macular surgery: results and complications
Fabio Patelli1, Paolo Radice, Giulio Zumbo
1Department of Ophthalmology, Villa Tiberia Clinic, Rome, Italy. f.patelli@tiscali.it
Purpose:
To report the safety and surgical outcome of 25-gauge transconjunctival sutureless vitrectomy for macular conditions.
Methods:
In a single-center, retrospective, noncomparative case series, 160 eyes of 150 patients underwent 25-gauge vitrectomy for different macular conditions: 108 eyes for idiopathic macular pucker, 24 for idiopathic macular hole, and 28 for tractional diabetic macular edema. Main outcome measures were surgical time, preoperative and 1-day intraocular pressure (IOP), preoperative and 1-month, 3-month, and 6-month visual acuity, intraoperative and postoperative complications, anatomical results, and cataract progression. All patients were observed up for at least 6 months.
Results:
Mean follow-up was 10 months (range, 6-20 months). Mean operative time +/- SD was 21 +/- 11 minutes. Mean 1-day IOP was 14 +/- 4 mmHg. No IOP was <8 mmHg on postoperative day 1. Mean overall preoperative visual acuity was 20/70, and mean overall postoperative visual acuity was 20/40 (P
Conclusions:
25-Gauge vitrectomy is a safe and effective procedure for macular surgery. The absence of intraoperative complications and relatively low rate of postoperative complications suggest that this technique is safe and effective for treating macular conditions.