A Method for Quantifying Upper Limb Performance in Daily Life Using Accelerometers
Published on: April 21, 2017
Comparison of Lifecorder EX and ActiGraph accelerometers under free-living conditions
James J McClain1, Cora L Craig, Susan B Sisson
1Department of Exercise and Wellness, Arizona State University, 7350 East Unity Ave., Mesa, AZ 85212-0180, USA.
Abstract:
The Kenz Lifecorder EX (LC; Suzuken Co. Ltd., Nagoya, Japan) offers several potentially attractive features for researchers and practitioners compared with accelerometers such as the ActiGraph (AG; ActiGraph Health Services, Fort Walton Beach, Fla.). The purposes of this study were (i) to evaluate the LC's intra-model reliability for outputs of steps and time spent in moderate, vigorous, and combined moderate plus vigorous physical activity (MVPA) and (ii) to compare the same LC vs. AG outputs under free-living conditions. Ten participants (n = 5 males) wore two LCs and one AG accelerometer during all waking hours on one day. Steps were outputted from all monitors. Additionally, two LC and five AG intensity derivations were used to assess time in moderate activity, vigorous activity, and MVPA. Intra-class correlations (ICC) were used to assess intra-model reliability between LCs. Paired t tests and repeated-measures analyses of variance (ANOVAs) were used to assess differences between the two LCs and LC vs. AG outputs of steps and time in various intensity derivations where appropriate. No significant differences were detected between outputs from different LCs (ICCs ranged from 0.95 to 0.99). The LC detected significantly fewer steps vs. AG (mean difference = 1516 steps). All LC vs. AG vigorous-intensity derivations provided similar outputs. Additionally, comparable estimates of MVPA time were produced by one of two LC intensity derivations compared with specific AG cut points established each by Freedson, Hendelman (walking), and Matthews. LC displayed high inter-model reliability. Although the LC detected fewer steps than the AG, the LC detects time in specific PA intensity categories comparable to several existing AG cut points.
Related Concept Videos
Measuring Acceleration Due to Gravity
A simple pendulum can be described as a point mass and a string. Meanwhile, a physical pendulum is any object whose oscillations are similar to a simple pendulum, but cannot be modeled as a point mass on a string because its mass is distributed over a larger area. The behavior of a physical pendulum can be modeled using the principles of...
Relative Motion Analysis - Acceleration
Holter Monitor: 24-Hour Monitoring
Average Acceleration