Related Experiment Video
Updated: Jul 13, 2026

E-Patient Counseling Trial (E-PACO): Computer Based Education versus Nurse Counseling for Patients to Prepare for Colonoscopy
Published on: August 1, 2019
Measuring access: how accurate are patient-reported waiting times?
E Rutland1, C Rowberry, R Patel
1Department of Genitourinary Medicine, Southampton University Hospitals NHS Trust, Royal South Hants Hospital, Southampton SO14 0YG, UK. emma_rutland@hotmail.com
Introduction:
A national audit of waiting times in England's genitourinary medicine clinics measures patient access. Data are collected by patient questionnaires, which rely upon patients' recollection of first contact with health services, often several days previously. The aim of this study was to assess the accuracy of patient-reported waiting times.
Methods:
Data on true waiting times were collected at the time of patient booking over a three-week period and compared with patient-reported data collected upon clinic attendance. Factors contributing to patient inaccuracy were explored.
Results:
Of 341 patients providing initial data, 255 attended; 207 as appointments and 48 'walk-in'. The accuracy of patient-reported waiting times overall was 52% (133/255). 85% of patients (216/255) correctly identified themselves as seen within or outside of 48 hours. 17% of patients (17/103) seen within 48 hours reported a longer waiting period, whereas 20% of patients (22/108) reporting waits under 48 hours were seen outside that period. Men were more likely to overestimate their waiting time (10.4% versus 3.1% p<0.02). The sensitivity of patient-completed questionnaires as a tool for assessing waiting times of less than 48 hours was 83.5%. The specificity and positive predictive value were 85.5% and 79.6%, respectively.
Conclusion:
The overall accuracy of patient reported waiting times was poor. Although nearly one in six patients misclassified themselves as being seen within or outside of 48 hours, given the under and overreporting rates observed, the overall impact on Health Protection Agency waiting time data is likely to be limited.
Related Concept Videos
Data Reporting and Recording
Uncertainty in Measurement: Reading Instruments
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Types of Reports III: Telephone and Verbal Reports
Here's an overview of each type:
Telephone Orders
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.