'LC-electrolyte effects' improve the bioanalytical performance of liquid chromatography/tandem mass spectrometric assays in supporting pharmacokinetic study for drug discovery
Related Experiment Video
Updated: Jul 13, 2026

Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
Published on: September 23, 2021
1Shanghai Center for DMPK Research, Shanghai Institute of Materia Medica, Chinese Academy of Sciences, Shanghai 201203, China.
Abstract:
The development of rapid and sensitive bioanalytical methods in a short time frame with acceptable levels of precision and accuracy is imperative for successful drug discovery. We previously reported that the use of a mobile phase containing an extremely low concentration of ammonium formate or formic acid increased analyte electrospray ionization (ESI) response and controlled against matrix effects. We designated these favorable effects 'LC-electrolyte effects'. In order to support rapid pharmacokinetic (PK) studies for drug discovery, we applied LC-electrolyte effects to the development of generic procedures that can be used to quickly generate reliable PK data for compound candidates. We herein demonstrate our approach using four model tested compounds (Compd-A, -B, -C, and -D). The analytical methods involve generic protein precipitation for sample clean-up, followed by application of fast liquid chromatographic (LC) gradients and the subsequent use of electrospray ionization tandem mass spectrometry (ESI-MS/MS) for individual measurement of the tested compounds in 20-microL plasma samples. Good linearity over the concentration range of 1.6 or 8-25000 ng/mL (r(2) > 0.99), precision (RSD, 0.45-13.1%), and accuracy (91-112%) were achieved through the use of a low dose of formic acid (0.4 mM or 0.015 per thousand) in the methanol/water-based LC mobile phase. The analytical method was quite sensitive, providing a lower limit of quantification of 1.6 pg on-column except for Compd-C (8 pg), and showed negligible ion suppression caused by matrix components. Finally, the assay suitability was demonstrated in simulated discovery PK studies of the tested compounds with i.v./p.o. dosing of rats. This new assay approach has been adopted with good results in our laboratory for many recent discovery PK studies.
More Related Videos
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
07:46Sheathless Capillary Electrophoresis–Mass Spectrometry for Metabolic Profiling of Biological Samples
Published on: October 1, 2016
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
High-Performance Liquid Chromatography: Types of Detectors
Ion-Exchange Chromatography
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Electrogravimetric Analysis: Overview
To test the completeness of the...