Diagnostic performance of multidetector CT angiography for assessment of coronary artery disease: meta-analysis
Piet K Vanhoenacker1, Majanka H Heijenbrok-Kal, Ruben Van Heste
1Department of Radiology and Medical Imaging, OLV Ziekenhuis Aalst, Moorselbaan 164, 9300 Aalst, Belgium. piet@vanhoenacker.be
Insights
Newer multidetector CT scanners significantly improve diagnostic accuracy for coronary artery disease assessment. These advanced systems also reduce the number of unassessable coronary segments, enhancing diagnostic reliability.
Area of Science:
- Cardiovascular Imaging
- Radiology
- Medical Diagnostics
Background:
- Coronary artery disease (CAD) remains a leading cause of mortality worldwide.
- Accurate non-invasive diagnostic tools are crucial for timely intervention.
- Multidetector computed tomographic (CT) angiography has emerged as a promising imaging modality for CAD assessment.
Purpose of the Study:
- To systematically review and meta-analyze the diagnostic performance of multidetector CT angiography for symptomatic coronary artery disease.
- To compare the diagnostic accuracy of different generations of multidetector CT scanners (4-, 16-, and 64-detector).
- To evaluate the proportion of nonassessable coronary arterial segments across different CT scanner generations.
Main Methods:
- A comprehensive literature search of PubMed and manual review was conducted for studies published between January 1998 and May 2006.
- Meta-analysis included 54 studies comparing multidetector CT angiography with conventional coronary angiography.
- Random-effects models were used to calculate pooled sensitivity, specificity, and diagnostic odds ratios.
Main Results:
- The 64-detector CT angiography demonstrated the highest pooled sensitivity (0.93) and specificity (0.96) for detecting significant stenosis.
- Diagnostic performance significantly improved with newer CT scanner generations (16- and 64-detector vs. 4-detector).
- The proportion of nonassessable coronary segments significantly decreased with advancements in CT technology.
Conclusions:
- Modern multidetector CT scanners offer significantly improved diagnostic performance for coronary artery disease.
- Advancements in CT technology have led to a reduction in nonassessable segments, enhancing clinical utility.
- Multidetector CT angiography is a reliable tool for evaluating symptomatic coronary artery disease.
Purpose:
To review the literature on the diagnostic performance of multidetector computed tomographic (CT) angiography for assessment of symptomatic coronary artery disease, with conventional coronary angiography as the reference standard.
Materials And Methods:
A PubMed and manual search of the literature published between January 1998 and May 2006 on use of multidetector CT angiography compared with coronary angiography in patients with symptomatic coronary artery disease was performed. Summary estimates of diagnostic odds ratio, sensitivity, and specificity were calculated. Random-effects models were used to compare the diagnostic performance of four-, 16-, and 64-detector CT angiographic units, and the proportion of nonassessable coronary arterial segments was evaluated.
Results:
Fifty-four studies were included in the meta-analysis: 22 studies with four-detector CT angiography, 26 with 16-detector CT angiography, and six with 64-detector CT angiography. The pooled sensitivity and specificity for detecting a greater than 50% stenosis per segment were 0.93 (95% confidence interval [CI]: 0.88, 0.97) and 0.96 (95% CI: 0.96, 0.97) for 64-detector CT angiography, 0.83 (95% CI: 0.76, 0.90) and 0.96 (95% CI: 0.95, 0.97) for 16-detector CT angiography, and 0.84 (95% CI: 0.81, 0.88) and 0.93 (95% CI: 0.91, 0.95) for four-detector CT angiography, respectively. Results of regression analysis indicated that the diagnostic performance significantly improved with the newer generations of multidetector CT scanners (64- and 16-detector vs four-detector units), adjusted for exclusion of nonassessable segments, and contrast agent concentration used (P < .05). Simultaneously, the nonassessable proportion of segments significantly decreased with the newer generations of multidetector CT scanners, adjusted for heart rate, prevalence of significant disease, and mean age.
Conclusion:
With the newer generations of multidetector CT scanners, the diagnostic performance for the assessment of coronary artery disease has significantly improved, and the proportion of nonassessable segments has decreased.
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Acute Coronary Syndrome III: Diagnostic Studies
Coronary Artery Disease V: Interprofessional Care
Imaging Studies for Cardiovascular System IV: CMRI
Atherosclerosis II: Clinical Manifestations and Diagnostic Tests