Related Experiment Video
Updated: Jul 13, 2026

07:03
In Situ Surface Temperature Measurement in a Conveyor Belt Furnace via Inline Infrared Thermography
Published on: May 30, 2020
Microwave radiometry for cement kiln temperature measurements
Karl D Stephan1, Lingyun Wang, Eric Ryza
1Department of Engineering and Technology, Texas State University, San Marcos, TX, USA.
Summary
Measuring cement kiln temperature is challenging. This study shows microwave radiometer data correlates with product chemistry, offering a new way to monitor kiln operations.
Area of Science:
- Materials Science
- Chemical Engineering
- Process Monitoring
Background:
- Accurate measurement of maximum cement kiln temperature is crucial for process control but remains difficult.
- Existing methods for temperature monitoring in cement kilns are often indirect or invasive.
Purpose of the Study:
- To present novel data demonstrating a correlation between cement kiln temperature and product chemistry.
- To validate the use of a microwave radiometer for in-situ cement kiln temperature measurement.
Main Methods:
- Utilized a microwave radiometer operating in the 12-13 GHz frequency range.
- Collected temperature data and product chemistry samples over an eight-hour period.
- Analyzed the relationship between radiometer-sensed temperature and chemical composition of the cement product.
Main Results:
- The study provides the first data showing a significant correlation between microwave radiometer-measured kiln temperature and cement product chemistry.
- The observed correlation persisted over an eight-hour operational period, indicating consistent performance.
Conclusions:
- Microwave radiometry offers a viable, non-invasive method for monitoring cement kiln temperatures.
- The correlation between temperature and product chemistry can be leveraged for improved process control and quality assurance in cement manufacturing.
Related Concept Videos
Measurement of Air Content in Concrete
Air content measurement in concrete is critical for ensuring structural integrity and durability of concrete structures, especially in environments prone to severe weather conditions. Accurate air content analysis optimizes concrete's resistance to freeze-thaw cycles and enhances its workability and strength. Several methods are standardized under ASTM guidelines to measure the air content in fresh concrete, each suitable for different concrete types and conditions.
The pressure method,...
The pressure method,...
Flame Photometry: Lab
In a flame photometer, when a solution like potassium chloride is aspirated into the flame, the solvent evaporates, leaving behind dehydrated salt. This salt dissociates into free gaseous atoms in their ground state. Some of these atoms absorb energy from the flame, leading to their excitation. The excited atoms return to the ground state, emitting photons at characteristic wavelengths. Because only electronic transitions are involved, the resulting emission lines are very narrow. The intensity...
Constant Volume Calorimetry
Calorimeters are useful to determine the heat released or absorbed by a chemical reaction. Coffee cup calorimeters are designed to operate at constant (atmospheric) pressure and are convenient to measure heat flow (or enthalpy change) accompanying processes that occur in solution at constant pressure. A different type of calorimeter that operates at constant volume, colloquially known as a bomb calorimeter, is used to measure the energy produced by reactions that yield large amounts of heat and...
Temperature Measurement Sites
A thermometer measures body temperature. The common sites for measuring body temperature are the oral cavity, axillary region, temporal artery, and skin surface, such as the forehead, abdomen, and axilla. True core body temperature is assessed in the rectum, tympanic membrane, pulmonary artery, esophagus, and urinary bladder.
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Mass Concreting
Mass concreting refers to the process of placing large volumes of concrete, such as in gravity dams. The heat generated during the cement hydration process and differential cooling rates within the concrete mass can lead to a temperature gradient, which can result in thermal cracks in the concrete mass.
To reduce the risk of such cracking, the concrete mix may incorporate low-heat cement and pozzolans to reduce the temperature rise. Pre-cooled angular aggregates and water-reducing admixtures...
To reduce the risk of such cracking, the concrete mix may incorporate low-heat cement and pozzolans to reduce the temperature rise. Pre-cooled angular aggregates and water-reducing admixtures...
Masonry in Cold and Hot Weather Conditions
In cold weather, masonry construction requires specific precautions to ensure mortar does not freeze before curing, as this can significantly weaken its strength and watertightness. Mortar temperature should be maintained between 60°F and 80°F to support proper hydration and curing. Below 40°F, mortar water must be heated, but should not exceed 120°F as high temperatures can reduce mortar's compressive and bond strength.
Other key practices include keeping masonry units and sand dry and...
Other key practices include keeping masonry units and sand dry and...

