Related Experiment Video
Updated: Jul 13, 2026

Rapid Mix Preparation of Bioinspired Nanoscale Hydroxyapatite for Biomedical Applications
Published on: February 23, 2017
Tribological behavior of plasma-sprayed carbon nanotube-reinforced hydroxyapatite coating in physiological solution
Kantesh Balani1, Yao Chen, Sandip P Harimkar
1Department of Mechanical and Materials Engineering, Florida International University, Miami, FL 33174, USA.
Abstract:
Wear behavior of plasma-sprayed carbon nanotube (CNT)-reinforced hydroxyapatite (HA) coating is evaluated in the simulated body fluid environment. Apart from enhancing the fracture toughness and providing biocompatibility, CNT-reinforced HA coating demonstrated superior wear resistance compared with that of hydroxyapatite coating without CNT. Initiation and propagation of microcracks during abrasive wear of plasma-sprayed hydroxyapatite coatings was suppressed by CNT reinforcement. Surface characterization and wear studies have shown that in addition to acting as underprop lubricant, CNTs provide reinforcement via stretching and splat-bridging for enhanced abrasion resistance in vitro.