Esophageal Heat Transfer for Patient Temperature Control and Targeted Temperature Management
Published on: November 21, 2017
Timing and reproducibility of access flow measurements using extracorporeal temperature gradients
Daniel Schneditz1, Isolde Bachler, Frank M van der Sande
1Institute of Physiology, Medical University of Graz, Austria.
Abstract:
The duration, accuracy, and reproducibility of a new access flow measuring technique was analyzed in a series of in vitro experiments using an extracorporeal line switch that allowed for almost instantaneous reversal of extracorporeal blood flow without disconnecting the blood lines. Access flow was modeled from the magnitude and time course of extracorporeal temperature changes caused by switching the blood lines. Ten tests were done with access flows covering a range from 410 to 1500 ml min. The coefficient of variation of triplicate access flow identifications was 3.8 +/- 1.5%. The mean bias between measured and modeled access flows was 54 +/- 54 ml min and independent of the range of measured access flows. The average time constant for temperatures to stabilize after switching the blood lines was 0.68 +/- 0.11 min. These results show that the instantaneous change in the direction of blood flow in proximal parts of the extracorporeal circulation produces a smooth change in extracorporeal temperatures that can be explained by a mathematical model incorporating access flow and that a reproducible measure for access blood flow can be obtained as one of the model parameters from that fit within a few minutes of switching the blood lines without the injection of indicator.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...