Related Experiment Video
Updated: Jul 13, 2026

The Supraclavicular Fossa Ultrasound View for Central Venous Catheter Placement and Catheter Change Over Guidewire
Published on: December 23, 2014
Does ultrasound-guided central line insertion reduce complications and time to placement in elective patients
Anthony Espinet1, Joel Dunning
1Department of Cardiothoracic Surgery, Freeman Hospital, Freeman Road, Newcastle-upon-Tyne NE7 7DN, UK. anthony.espinet@nuth.northy.nhs.uk
Abstract:
A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was whether ultrasound probe central line placement reduced complications and time to placement in patients undergoing coronary artery bypass grafting surgery. Altogether, 193 papers were found from Medline using the reported search of which 6 papers presented the best evidence to answer the clinical question. The author, journal, date and country of publication, patient group studied, study type, relevant outcomes, results, and study weaknesses and comments were tabulated. We conclude that in patients with a potentially difficult central line insertion, the ultrasound technique reduces complications and time to insertion. However, in those patients where no difficulty is predicted, there is no evidence that the ultrasound technique confers any advantage.
Related Concept Videos
Cardiac Catheterization III: Left Heart Catheterization
Cardiac Catheterization I: Pre-Procedure Overview
Cardiac Catheterization IV: Nursing Management