Transoesophageal echocardiography accurately detects cardiac output variation: a prospective comparison with
1Universidad de Chile, Hospital Clínico y Facultad de Medicina, Anestesiología, Santiago, Chile. vparra@med.uchile.cl
Background And Objective:
Intraoperative Doppler ultrasound can be used to measure cardiac output by transoesophageal echocardiography. Recently, its reliability, when compared to the thermodilution technique, has been questioned. The purpose of this study was to compare intraoperative changes in cardiac output measured by echo-Doppler and by thermodilution in cardiac surgery. We also assessed the agreement between the techniques.
Methods:
Fifty cardiac surgical patients (38 male, 12 female, mean age of 63.4 +/- 14.3 yr) were prospectively included after approval by the Ethics Committee of the Institution. Cardiac output was assessed by thermodilution, with 10 mL saline at 12 degrees C, and simultaneously and blindly by echo-Doppler in deep transgastric view with pulsed wave Doppler at the level of the left ventricular outflow tract. Matched thermodilution cardiac output and echo-Doppler cardiac output measurements were taken three times at the end of expiration, both pre- and post-cardiopulmonary bypass.
Results:
Echo-Doppler measurements were obtained in 44 patients (88%). In three patients, Doppler recordings could not be obtained adequately, and three developed left ventricular outflow tract obstruction after bypass. Bland-Altman analysis revealed a bias of 0.015 L min(-1), with narrow limits of agreement (-1.21 to 1.22 L min(-1)) and 29.1% error. Echo-Doppler was accurate (92% sensitivity and 71% specificity, P = 0.008 by receiver operating characteristic curves) for detecting more than 10% of change in thermodilution cardiac output. There were no complications related to the study.
Conclusions:
The agreement between cardiac output by echo-Doppler and by thermodilution is clinically acceptable and transoesophageal echocardiography is a reliable tool to assess significant cardiac output changes in a population of selected patients.
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...