Pulse Wave Velocity Testing in the Baltimore Longitudinal Study of Aging
Published on: February 7, 2014
Noninvasive pulse waveform analysis in clinical trials: similarity of two methods for calculating aortic systolic
Audrey Adji1, Kozo Hirata, Sonja Hoegler
1St. Vincent's Clinic, University of New South Wales, MPU/VCCRI Department, Sydney, New South Wales, Australia. ar_adji@optusnet.com.au
Background:
Concerns persist about the validity of generalized transfer function-derived, aortic blood-pressure measurements during the administration of vasoactive agents in clinical trials. Hence, we compared this transfer-function method with another, which estimates aortic systolic pressure directly from the late systolic shoulder of the radial pressure wave, after administration of placebo, ramipril, or atenolol.
Methods:
We recorded radial pressure pulse waveforms, using a commercially available system, in 30 subjects with >or=1 coronary risk factor in an acute study of ramipril at 10 mg and atenolol at 100 mg. Directly recorded radial and derived aortic pressure pulse waveforms were examined individually and were ensemble-averaged, and the difference between radial and aortic pressure responses was examined.
Results:
The late systolic shoulder response from radial waveforms was reduced by 15.8 mm Hg (SD, 12.2 mm Hg) more with ramipril than with atenolol. This was similar to a difference of 14.6 mm Hg (SD, 11.2 mm Hg) calculated for the aortic systolic pressure response using the transfer-function technique. Ramipril caused a greater reduction in the aortic systolic pressure response (22.2 mm Hg), whereas with atenolol, there was a modest decrease (7.6 mm Hg). The mean difference between aortic systolic pressures measured from direct radial waveforms and from derived aortic pressure between 3 and 5 h after dosing under all circumstances was 1.6 mm Hg (SD, 8.9 mm Hg).
Conclusions:
Central pressure derived from radial pressure waveforms using a generalized transfer function gave similar results for central pressure measured directly from radial waveforms. The hemodynamic benefits of angiotensin-converting enzyme inhibitor, angiotensin receptor blocker, and calcium channel blocker over beta-blocker antihypertensive therapy in recent trials were confirmed by this study.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: