Related Experiment Video
Updated: Jul 13, 2026

A Simplified Stepwise Approach to Echo Guidance during Percutaneous Mitral Valve Repair
Published on: October 16, 2021
Failure of guideline-based anticoagulation in a patient with mitral prosthetic valve and recurrent thromboembolism
Halil Mutlu1, Mustafa E Yerlioglu, William K Levy
1Department of Medicine, Berkshire Medical Center, Pittsfield, Massachusetts 01201, USA. histanbul@yahoo.com
Abstract:
Prosthetic valve (PV)-related thromboembolism is a rare but serious complication of implanted mechanical valves. There is not a design that has yet achieved mechanical perfection; therefore, using these mechanical valves is not free of mortality and morbidity. Some of the complications of using such valves include PV thrombosis, systemic embolization, bleeding, endocarditis, perivalvular leak, and structural valve failure. These valves are thrombogenic, and their use requires anticoagulation postoperatively to prevent systemic embolization and PV thrombosis. This intervention also carries the risk of bleeding, which can be detrimental for a subset of patients, especially elderly, pregnant, and those with other systemic comorbidities. In this case we present a patient with recurrent thromboembolic events and a nonobstructing St. Jude mitral PV thrombosis despite vigorous anticoagulation with Coumadin (Bristol-Myers Squibb Co., Princeton, NJ) and aspirin.
Related Concept Videos
Mitral Stenosis III: Medical Management
Mitral Regurgitation III: Medical Management
Mitral Valve Prolapse II: Assessment and Management
Mitral Regurgitation IV: Nursing Management
Mitral Stenosis II: Clinical features and Diagnostic Tests
Endocarditis III: Medical Management