A systematic evaluation of chip-based nanoelectrospray parameters for rapid identification of proteins from a complex
Ana Gabriela Pereira-Medrano1, Alistair Sterling, Ambrosius P L Snijders
1Biological and Environmental Systems Group, Department of Chemical and Process Engineering, University of Sheffield, Sheffield, United Kingdom.
Abstract:
HPLC-MS/MS is widely used for protein identification from gel spots and shotgun fractions. Although HPLC has well recognized benefits, this type of sample infusion also has some undesirable attributes: relatively low sample throughput, potential sample-to-sample carryover, time-varying sample composition, and no option for longer sample infusion for longer MS analyses. An automated chip-based ESI device (CB-ESI) has the potential to overcome these limitations. This report describes a systematic evaluation of the information-dependant acquisition (IDA) and sample preparation protocols for rapid protein identification from a complex mixture using a CB-ESI source compared with HPLC-ESI (gradient and isocratic elutions). Cytochrome c and a six-protein mixture (11-117 kDa) were used to develop an IDA protocol for rapid protein identification and to evaluate the effects of sample preparation protocols. MS (1-10 s) and MS/MS (1-60 s) scan times, sample concentration (50-500 fmol/microL), and ZipTipC(18) cleanup were evaluated. Based on MOWSE scores, protein coverage, experimental run time, number of identified proteins, and reproducibility, a 12.5 min experiment (22 cycles, each with one 3 s MS and eight 10 s MS/MS scans) was determined to be the optimal IDA protocol for CB-ESI. This work flow yielded up to 220% greater peptide coverage compared with gradient HPLC-ESI and provided protein identifications with up to a 2-fold higher throughput rate than either HPLC-ESI approach, whilst employing half the amount of sample over the same time frame. The results from this study support the use of CB-ESI as a rapid alternative to the identification of protein mixtures.
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...