Related Experiment Video
Updated: Jul 13, 2026

3D Hydrogel Scaffolds for Articular Chondrocyte Culture and Cartilage Generation
Published on: October 7, 2015
Hyaluronan-based scaffolds to tissue-engineer cartilage implants for laryngotracheal reconstruction
Mark Weidenbecher1, James H Henderson, Harvey M Tucker
1Department of Orthopaedics, Case Western Reserve University, Cleveland, Ohio 44106, USA. m.weidenbecher@gmail.com
Objectives:
Donor site morbidity, including pneumothorax, can be a considerable problem when harvesting cartilage grafts for laryngotracheal reconstruction (LTR). Tissue-engineered cartilage may offer a solution to this problem. This study investigated the feasibility of using Hyalograft C combined with autologous chondrocytes to tissue engineer cartilage grafts for LTR in rabbits.
Study Design:
Animal study.
Methods:
Eighteen New Zealand white rabbits underwent LTR: 12 rabbits received autologous tissue-engineered cartilage grafts and 6 animals, serving as a positive control group, native auricular cartilage. To determine any differences in response to the site of implantation and any potential immune response to the scaffold, a second piece of engineered neocartilage and a non-cell-loaded scaffold were inserted paralaryngeally into a subset of the rabbits. The rabbits were sacrificed 3, 6, 8, 10, and 12 weeks after the LTR and their larynx examined.
Results:
None of the 18 rabbits showed signs of respiratory distress. A smooth, noninflammatory scar was visible intraluminally. Histologically, the native auricular cartilage implants showed excellent integration without any signs of inflammation or cartilage degradation. In contrast, all tissue-engineered grafts and empty scaffolds revealed marked signs of an unspecific foreign body reaction, leading to a complete degradation of the neocartilage, whether implanted para- or intralaryngeally.
Conclusion:
In contrast to the success with which Hyalograft C has been applied in articular defect repair, our results indicate that, in rabbits, Hyalograft C initiates a foreign body reaction if implanted intra- or paralaryngeally, leading to cartilage degradation and possible graft failure. These findings suggest limitations on the environment in which Hyalograft C can be applied.