Related Experiment Video
Updated: Jul 13, 2026

A Reversible, Non-invasive Method for Airway Resistance Measurements and Bronchoalveolar Lavage Fluid Sampling in Mice
Published on: April 13, 2010
Computational fluid dynamics can detect changes in airway resistance in asthmatics after acute bronchodilation
J W De Backer1, W G Vos, A Devolder
1Department of Pulmonology, University Hospital Antwerp, Wilrijkstraat 10, 2650 Edegem, Belgium. Jan.DeBacker@ua.ac.be
Abstract:
The effect of a bronchodilator in asthmatics is only partially described by changes in spirometric values since no information on regional differences can be obtained. Imaging techniques like high-resolution computed tomography (HRCT) provide further information but lack detailed information on specific airway responses. The aim of the present study was to improve the actual imaging techniques by subsequent analysis of the imaging data using computational fluid dynamics (CFD). We studied 14 mild to moderately severe asthmatics. Ten patients underwent HRCT before and 4h after inhalation of a novel long acting beta(2) agonist (LABA) that acts shortly after inhalation. Four patients were studied for chronic effects and underwent CT scans twice after adequate wash-out of bronchodilators. In the active group, a significant bronchodilator response was seen with a forced expiratory volume in 1s (FEV1) increase of 8.78 +/- -6.27% pred vs -3.38 +/- 6.87% pred in the control group. The changes in FEV1 correlated significantly with the changes in distal airway volume (r = 0.69, p = 0.007), total airway resistance (r = -0.73, p = 0.003) and distal airway resistance (r = -0.76, p = 0.002) as calculated with the CFD method. The changes in distal R(aw) were not fully homogeneous. In some patients with normal FEV1 at baseline, CFD-based changes in R(aw) were still detectable. We conclude that CFD calculations, based on airway geometries of asthmatic patients, provide additional information about changes in regional R(aw). All changes in the CFD-based calculated R(aw) significantly correlate with the observed changes in spirometric values therefore validating the CFD method for the studied application.
Related Concept Videos
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Chronic Obstructive Pulmonary Disease III: Chronic Bronchitis Features
Asthma: Pathogenesis and Management
Asthma is classified as allergic and non-allergic. Allergens such as dust mites, pollen, and pet dander trigger allergic asthma, while factors like cold air, intense emotions, or exercise can induce non-allergic asthma.
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Chronic Obstructive Pulmonary Disease-II: Pathophysiology
Chronic Inflammation
Asthma I: Introduction