Comparison of cardiac output in OPCAB: bolus thermodilution technique versus pulse contour analysis
1Department of Anaesthesiology and Critical Care and Department of Cardiac Surgery, Escorts Heart Institute and Reasearch Centre, New Delhi.
Abstract:
The study was designed to evaluate the clinical agreement between intermittent bolus thermodilution technique and pulse contour analysis technique. Sixty patients with normal left ventricular function undergoing elective off-pump coronary bypass surgery were included in this prospective study. In addition to routine monitoring, a 7.5F pulmonary artery thermodilution catheter via right internal jugular vein and a 4F arterial thermodilution catheter into femoral artery were also placed. Cardiac output measurements were compared before induction, after induction, after sternotomy, during the various anastomoses, post-protamine and post-sternal closure. Statistical analysis was performed using analysis of agreement to assure bias distribution of differences between the two methods by using Bland and Altman analysis. The cardiac output values obtained at preinduction, post-induction, and post-sternal closure time points showed good agreement, whereas the values obtained during the various anastomoses showed significant differences (p <0.05). Therefore it was concluded that pulse contour analysis cannot be relied upon completely whenever there is a change in the position of heart or alteration in systemic vascular resistance. But the trends in cardiac output were in complete agreement during the entire procedure.
Related Concept Videos
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...