Related Experiment Video
Updated: Jul 13, 2026

A Simplified Model for Heterotopic Heart Valve Transplantation in Rodents
Published on: September 21, 2021
Long-term morphological changes in a cryopreserved pulmonary valve homograft
Adriana Luk1, Jagdish Butany, Sarah A Erlich
1Department of Pathology, Toronto General Hospital/University Health Network, Toronto, ON, Canada.
Abstract:
Pulmonary homografts (PHs) are frequently used to replace the native pulmonary valve in the Ross procedure, and in the reconstruction of the right ventricular outflow tract. The case of a 25-year-old man whose PH was replaced 12 years after undergoing the Ross procedure is reported. The clinical cause of the PH failure was stenosis. Morphological studies showed cusp tissue degeneration with tears and calcification, as well as pannus growth on the flow and nonflow surfaces of the cusps and the pulmonary artery graft. The durability of this PH was likely due to a combination of low pressure on the right side of the heart and the patient's age at surgery.