A comparative study of thoracic radiation doses from 64-slice cardiac CT
1Department of Radiology, Columbia University and New York Presbyterian Hospital, 177 Fort Washington Avenue, Milstein Bldg Room 3-265B, New York, NY 10032-3784, USA. eln1@columbia.edu
Abstract:
The goal of this study was to measure radiation doses for 64-slice cardiac CT angiography studies and to study the dose-savings features of these CT scanners. This was done using various phantoms. These radiation doses were compared with those from typical helical body CT scans, fluoroscopy cardiac catheterization studies and mammography examinations. Radiation measurements were made with a CT ionization detector and a solid state dosimeter. A GE 64-slice Lightspeed VCT and a Siemens Somatom Sensation 64 CT were used to scan a standard 32 cm acrylic phantom and an anthropomorphic phantom. Data were collected in axial and various gated cardiac helical modes. Organ doses and the effective doses were calculated from the measurements. In gated CT cardiac mode with the 32 cm acrylic phantom, the measured radiation doses per study were generally three to seven times greater than those from typical body helical CT examinations; the range depended upon selectable scan parameters. With the anatomical phantom, the surface doses in the anteroposterior (AP) plane were typically 20-60% higher than those measured using the 32 cm phantom. The lateral surface doses were -4% to +15%. These results can be attributed to the shorter AP dimension and the air in the lungs. The CT skin entrance radiation doses were 80-90% less than diagnostic cardiac catheterization studies, and organ doses were similar. Because 64-slice cardiac gated CT uses pitches equal to 0.20-0.27 and high mAs values, the patient radiation doses are appreciably higher than in routine body CT examinations. The female breast, which could receive a radiation dose 10-30 times that received from mammography screening, is an organ of particular concern.
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT