Related Experiment Video
Updated: Jul 13, 2026

Esophageal Heat Transfer for Patient Temperature Control and Targeted Temperature Management
Published on: November 21, 2017
Observer-based monitoring of heat exchangers
Carlos-Manuel Astorga-Zaragoza1, Víctor-Manuel Alvarado-Martínez, Arturo Zavala-Río
1CENIDET, Interior Internado Palmira S/N, Col. Palmira, C.P. 62490, Cuernavaca, Morelos, Mexico. astorga@cenidet.edu.mx <astorga@cenidet.edu.mx>
Abstract:
The goal of this work is to provide a method for monitoring performance degradation in counter-flow double-pipe heat exchangers. The overall heat transfer coefficient is estimated by an adaptive observer and monitored in order to infer when the heat exchanger needs preventive or corrective maintenance. A simplified mathematical model is used to synthesize the adaptive observer and a more complex model is used for simulation. The reliability of the proposed method was demonstrated via numerical simulations and laboratory experiments with a bench-scale pilot plant.
Related Concept Videos
Bioreactor Controls-I
Calorimetry
Mechanisms of Heat Transfer II
Mechanisms of Heat Transfer
Conduction, accounting for approximately 3% of body heat loss at rest, is the process of exchanging heat between molecules of two materials in direct contact. This can result in both heat loss and gain. For instance, when the body is submerged in water, which conducts heat 20 times more effectively than air, it can either lose or gain significant heat.
Mechanism of heat transfer
Mechanisms of Heat Transfer I