Using mean field approach independent component analysis to fatty acid characterization with overlapped GC-MS signals

Maryam Vosough1

  • 1Chemistry and Chemical Engineering Research Center of Iran, P.O. Box 14335-186, Tehran, Iran. vosough@ccerci.ac.ir

Analytica Chimica Acta
|August 28, 2007
PubMed

Related Concept Videos

Mass Spectrometry: Complex Analysis01:21

Mass Spectrometry: Complex Analysis

Mass spectrometry is an important technique for the identification of pure compounds. However, it has some limitations for the analysis of complex mixtures, often due to excessive fragmentation making the spectrum too complicated to decipher. Mass spectrometry can be combined with suitable separation methods in sequence, forming hyphenated methods, which are useful in the analysis of complex mixtures.
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
NMR and Mass Spectroscopy of Carboxylic Acids01:30

NMR and Mass Spectroscopy of Carboxylic Acids

In ¹H NMR spectroscopy, acidic protons (–COOH) of carboxylic acids are highly deshielded and absorb far downfield, at around 9–12 ppm. The chemical shift value depends on the concentration and solvent used.
While α protons of carboxylic acids absorb at 2–2.5 ppm, β protons absorb further upfield.
Carboxylic acids are easily identified by dissolving them in deuterium oxide, which results in a rapid exchange of the acidic protons with deuterium. This leads to the disappearance of the acidic...
Gas Chromatography–Mass Spectrometry (GC–MS)01:14

Gas Chromatography–Mass Spectrometry (GC–MS)

Gas chromatography–mass spectrometry (GC–MS) is the combination of analytical techniques of gas chromatography and mass spectrometry in a single instrument for analyzing a mixture of compounds. The gas chromatograph separates the compounds in the mixture, and the mass spectrometer analyzes each compound separately to determine the molecular masses and molecular structures.
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Mass Spectrometry: Long-Chain Alkane Fragmentation01:18

Mass Spectrometry: Long-Chain Alkane Fragmentation

The molecular ions of linear alkanes prefer to fragment at the carbon-carbon bond away from the end of the chain since the cleavage of an inner bond creates a stable carbocation and a stable radical. Consequently, the mass signals of linear alkanes feature intense peaks in the middle of the mass-to-charge ratio plot with weaker peaks on either end. The fragmentation of each carbon-carbon bond with the release of a methyl group in each splitting leads to prominent peaks in the mass spectra...
Mass Spectrometry: Branched Alkane Fragmentation01:29

Mass Spectrometry: Branched Alkane Fragmentation

This lesson delves into the mass spectrometry of branched alkane fragmentation. Branched alkanes possess secondary or tertiary carbon atoms, which generate relatively stable carbocations if the cleavage occurs at the branching point. The high stability of carbocations drives the instant fragmentation of branched alkanes. Accordingly, the branched alkane's molecular ion peak is very weak or invisible in the mass spectra, especially in comparison to a linear alkane.
High-Resolution Mass Spectrometry (HRMS)01:15

High-Resolution Mass Spectrometry (HRMS)

The resolution of a mass spectrometer depends on the efficiency of separating ions with different ion masses. The mass of an atom is approximated to the sum of the masses of protons and neutrons inside, considering the masses of protons and neutrons as equal. However, the masses of the proton (1.6726 × 10−24 g) and neutron (1.6749 × 10−24 g) are not truly equal. There is a minor error in the expression of atomic masses relative to the simplest atom of hydrogen. For example, the mass of helium...