Related Experiment Video
Updated: Jul 12, 2026

Assessment of Boron Doped Diamond Electrode Quality and Application to In Situ Modification of Local pH by Water Electrolysis
Published on: January 6, 2016
Voltammetric determination of boron by using Alizarin Red S
Ibrahim Sahin1, Nuri Nakiboğlu
1Balikesir University, Necatibey Education Faculty, Chemistry Education Division, Balikesir, Turkey.
Abstract:
A novel voltammetric method for boron determination in ppb level is described. Boron complexes with Alizarin Red S (ARS) and the complex, as well as the free ligand, both adsorbs on a hanging mercury drop electrode. The method is based on the monitoring the anodic peak of the complex at -0.47 V in ammonium acetate-phosphate buffer (pH 7). The maximum peak current was obtained by scanning the potential from -700 mV versus Ag/AgCl to more positive potentials without accumulation in the presence of 1 x 10(-6) mol L(-1) of ARS. The instrumental parameters were mainly differential pulse mode with a pulse duration of 0.02 s and a scan rate of 5 mV s(-1). The limit of detection based on signal to ratio of 3 was calculated as 15 microgL(-1). The calibration plot for boron was linear in the range of 0-500 microg L(-1). The interference of various ions was examined and serious interference was observed from antimony(III). The relative standard deviation was found to be 5.1% for the 100 microg L(-1) boron level (n=10). The method was applied to the determination of boron in water and seawater samples with high boron content. The results obtained from the developed method were compared with Azomethine-H-method and no statistically significant difference was found.
More Related Videos
05:03Using Alizarin Red Staining to Detect Chemically Induced Bone Loss in Zebrafish Larvae
Published on: December 28, 2021
12:48Measuring Cation Transport by Na,K- and H,K-ATPase in Xenopus Oocytes by Atomic Absorption Spectrophotometry: An Alternative to Radioisotope Assays
Published on: February 19, 2013
Related Concept Videos
Redox Titration: Overview
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Redox Titration: Other Oxidizing and Reducing Agents
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Redox Titration: Iodimetry and Iodometry