Are changes in blood-ethanol concentration during storage analytically significant? Importance of method imprecision
1Department of Forensic Genetics and Forensic Chemistry, National Board of Forensic Medicine, Linköping, Sweden. wayne.jones@rmv.se
Background:
Knowledge about the stability of drugs and metabolites in biological fluids is important information when the analytical results are evaluated and interpreted. This study examines changes in blood-ethanol concentration (BEC) during the storage of specimens for up to 12 months at 4 degrees C.
Methods:
Venous blood samples were taken from drunk drivers in evacuated glass tubes containing sodium fluoride and potassium oxalate as chemical preservatives. The concentrations of ethanol in blood were determined in duplicate by headspace gas chromatography on arrival at the laboratory and again after storage in a refrigerator at 4 degrees C for up to 12 months.
Results:
The relationship between the standard deviation (SD) of analysis of ethanol at concentration intervals of 0.2 mg/g (BEC) was defined by the linear regression equation SD=0.00243+0.0104 BEC (r=0.99). At a mean BEC of 1.64 mg/g, the SD was 0.019 mg/g which corresponds to a coefficient of variation of 1.1%. The mean decrease in BEC (+/-SD) between first and second analysis was 0.105+/- 0.0686 mg/g (t=19.3, d.f.=158, p<0.001) and the loss of alcohol was positively correlated with the duration (days) of storage (r=0.44, p<0.001), although with large inter-tube variations. A correlation also existed (r=0.23, p<0.01) between the loss of ethanol and the starting BEC. When blood samples (n=49) were opened 17 times to remove aliquots for analysis over 6.5 months, the BEC decreased by 0.217+/-0.054 mg/g compared to a fall of 0.101+/-0.076 mg/g in tubes kept unopened. None of the blood samples showed a significant increase in BEC after storage.
Conclusions:
To be considered analytically significant, the BEC had to decrease by 0.013 (2.6%), 0.028 (1.9%) and 0.045 mg/g (1.8%), respectively at starting concentrations of 0.5, 1.5 and 2.5 mg/g.
Related Concept Videos
¹H NMR of Labile Protons: Temporal Resolution
The –OH proton in alcohols typically appears in the range of δ 2 to 5 ppm but can vary depending on the specific...
Data Validation
Key parameters for method validation include:
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Sample Handling
Samples should be transported carefully from collection points to the laboratory. They should be properly sealed and clearly labeled to prevent cross-contamination. To preserve the sample integrity, optimal temperature conditions during transport are essential. This could involve using...
Microbes in Beverage Production
Statistical Analysis: Overview
One of the most commonly used statistical quantifiers is the mean, which is the ratio between the sum of the numerical values of all results and the...