Continuous-flow particle separation by 3D Insulative dielectrophoresis using coherently shaped, dc-biased, ac

Benjamin G Hawkins1, A Ezekiel Smith, Yusef A Syed

  • 1Department of Biomedical Engineering, School of Applied and Engineering Physics, Cornell University, Ithaca, New York 14853, USA.

Analytical Chemistry
|September 4, 2007
PubMed

Related Concept Videos

Dielectric Polarization in a Capacitor01:31

Dielectric Polarization in a Capacitor

The presence of a dielectric medium in a capacitor not only changes the voltage and capacitance but also affects the electric field. In general, dielectrics can be of two types: polar and nonpolar. In a polar dielectric, the positive and negative charges in the molecules are separated by a distance and hence have a permanent dipole moment. In contrast, no such charge separation exists in a nonpolar dielectric, however the nonpolar molecules get polarized in the presence of an external electric...
Induced Electric Fields: Applications01:27

Induced Electric Fields: Applications

An important distinction exists between the electric field induced by a changing magnetic field and the electrostatic field produced by a fixed charge distribution. Specifically, the induced electric field is nonconservative because it does not work in moving a charge over a closed path. In contrast, the electrostatic field is conservative and does no net work over a closed path. Hence, electric potential can be associated with the electrostatic field but not the induced field. The following...
Electrostatic Boundary Conditions in Dielectrics01:27

Electrostatic Boundary Conditions in Dielectrics

When an electric field passes from one homogeneous medium to another, crossing the boundary between the two mediums imparts a discontinuity in the electric field. This results in electrostatic boundary conditions that depend on the type of mediums the field propagates through.
Consider a case where both the mediums across a boundary are two different dielectric materials. Recall that the electric field and electric displacement are proportional and related through the material's permittivity.
Capillary Electrophoresis: Instrumentation01:20

Capillary Electrophoresis: Instrumentation

Capillary electrophoresis instrumentation typically consists of several key components. A high-voltage power supply generates the electric field necessary for the separation by connecting to an anode (the positively charged electrode) and a cathode (the negatively charged electrode) located in buffer reservoirs at each end of the capillary tube. The system includes a sample vial, a fused silica capillary tube coated with polyimide for mechanical strength through which the sample components...
Capillary Electrophoresis: Applications01:30

Capillary Electrophoresis: Applications

Capillary electrophoretic separations offer various modes, each with unique applications. These modes include capillary zone electrophoresis, capillary gel electrophoresis, capillary array electrophoresis, capillary isoelectric focusing, capillary isotachophoresis, micellar electrokinetic chromatography, and capillary electrochromatography.
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Electrochemical Systems01:24

Electrochemical Systems

Electrochemical systems provide a fascinating insight into the dynamic interplay of charged species within various phases. One notable example is the interaction between a membrane permeable to K⁺ ions but not to Cl⁻ ions, separating an aqueous KCl solution from pure water. As K⁺ ions diffuse through the membrane, they generate net charges on each phase, leading to a potential difference between them.Similarly, when a piece of Zn is immersed in an aqueous ZnSO₄ solution, the Zn metal, composed...