[The influence of different respiratory frequencies on hemodynamics in patients on artificial ventilation]
1Emergency Intensive Care Unit, Drum Tower Hospital Affiliated to Nanjing University Medical School, Nanjing 210008, Jiangsu, China. ICUguqin@yahoo.com.cn
Objective:
To discuss the influence of different mechanical respiratory frequencies on hemodynamics in patients on mechanical ventilator.
Methods:
Twelve critical patients during weaning from mechanical ventilation with bi-level positive airway pressure (BiPAP) were studied. The ventilatory support was modified by changing the mechanical respiratory frequency only, with inspiratory airway pressure and positive end-expiratory pressure (PEEP) kept constant. Mechanical respiratory frequency was set as follows: 5, 10, 15 and 20 breaths per minute in randomized order. Respiratory mechanics, oxygenation and hemodynamics were determined and recorded 20 minutes after the change in ventilatory parameters.
Results:
(1)With the increase in mechanical respiratory rate, the mean pressure (Pmean) increased, minute ventilatory volume in control ventilation (V(Espont)) were also significantly increased, but minute ventilatory volume in spontaneous breaths (V(Espont)) were decreased (all P<0.01). There were no change in the total respiratory frequencies, minute ventilatory volume (V(E)), partial pressure of carbon dioxide in artery (PaCO(2)) and oxygenation index (PaO(2)/FiO(2), all P>0.05). (2)With the decrease in mechanical respiratory frequencies, stroke volume index(SI), cardiac output index(CI), global end-diastolic volume index(GEDVI) and intrathoracic blood volume index (ITBVI )were also increased (all P<0.01), but heart rate (HR), central venous pressure (CVP), mean artery pressure (MAP), systemic vascular resistance index (SVRI) and extravascular lung water index (EVLWI) were relatively stable (all P>0.05). (3)There was significant positive correlation between CI and GEDVI (r=0.569, P<0.01).
Conclusion:
With an increase in the ratio of spontaneous breaths to control ventilation in patients on mechanical ventilator, cardiac preload is increased, so cardiac output is also increased.
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Factors Affecting Respiration
Respiratory Volumes and Capacities I
Chemical Factors Affecting Respiration Centers
CO2 has a potent influence on respiration and is strictly regulated. Under...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...