Related Experiment Video
Updated: Jul 12, 2026

Application of Laparoscopic Ultrasonography in Primary Choledochal Suture during Combined Two-lens Surgery
Published on: March 28, 2025
Evaluation of gallbladder motility: comparison of two-dimensional and three-dimensional ultrasonography
Susanne Stads1, Niels G Venneman, Robert C H Scheffer
1Gastrointestinal Research Unit, Depts. of Gastroenterology and Surgery, University Medical Center Utrecht, The Netherlands.
Abstract:
Since impaired gallbladder emptying contributes to gallstone formation, the evaluation of gallbladder motility requires accurate methodology. Recently developed 3-dimensional ultrasonography may take into account various gallbladder shapes more accurately than conventional 2-dimensional ultrasonography. Therefore, volumes of water-filled balloons of various sizes were determined in vitro by 2-dimensional ultrasonography with the sum of cylinders method and by 3-dimensional ultrasonography. Also, in 15 gallstone patients and 6 healthy volunteers, fasting gallbladder volumes and postprandial motility were determined by both methods. Volumes of water-filled balloons as measured by both methods correlated strongly with true volumes (R= 0.93 for 2-dimensional and R = 0.98 for 3- dimensional ultrasonography). Gallbladder volumes measured by both methods were also correlated (R = 0.66, P <0.001). In gallstone patients, 3-dimensional ultrasonography yielded smaller gallbladder volumes than 2-dimensional ultrasonography (P = 0.007), but not in healthy subjects. With both methods, gallstone patients exhibited decreased postprandial gallbladder motility compared to healthy subjects. In conclusion, gallbladder volume measurements by 3-dimensional and 2-dimensional ultrasonography are strongly correlated.Nevertheless, in gallstone patients, gallbladder volumes by 3-dimensional ultrasonography tend to be smaller than by 2-dimensional ultrasonography, possibly due to interference of gallstones with the volume measurement.
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Imaging Studies II: Ultrasonography
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Imaging Studies VI: Voiding Cystourethrography and Cystography
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...