[The effect of dead space fraction on weaning from mechanical ventilation in COPD patients]
Raymond Farah1, Nicola Makhoul
1Department of Internal Medicine F, Western Galilee Hospital, Nahariya, Israel. Raymond.Farah@naharia.health.gov.il
Background:
Chronic Obstructive Pulmonary Disease (COPD) is a common disease that tends to occur worldwide. Physiologically, COPD represents a disruption in ventilation and in the exchange of gases in the lungs. Laboratory tests indicate elevated CO2 level, gradual reduction of the levels of oxygen and pH in arterial blood, and a consequent rise in the Dead Space Fraction (DSF) of the lungs.
Objective:
Patients with COPD represent a large portion of those artificially ventilated in the Intensive Care Unit (ICU). In an attempt to develop a prognostic tool for the length of treatment, we compared the proportion of DSF to the length of artificial respiration.
Methods:
This study included 49 patients receiving ventilation due to exacerbation of COPD. Each patient's arterial blood gases (ABG) were measured upon admission. PECO2 was tested using a Datex S/5 instrument. Subsequently, DSF was calculated using the Bohr equation. Statistical data was analyzed using the SPSS-11 program.
Results:
Patients included in the study were respirated from 5 to 161 hours (average 40 +/- 47). In addition to ABG measurements, PECO2 levels were measured and DSF calculated for each patient. DSF values varied from 0.22 to 0.74 (average 0.119 +/- 0.489). No correlation was found between DSF and length of artificial respiration. These findings do not contribute to the evaluation of the patient's condition nor do they enable us to predict the length of treatment necessary.
Conclusion:
Evaluation of Dead Space Fraction does not provide a factor in estimating the length of treatment for patients with acute respiratory failure due to Chronic Obstructive Pulmonary Disease (COPD).
Related Concept Videos
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Respiratory Volumes and Capacities
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation I: Indication and Settings
Atelectasis II: Pathophysiology