Automated on-line preconcentration of palladium on different sorbents and its determination in environmental samples
Fuensanta Sánchez Rojas1, Catalina Bosch Ojeda, José Manuel Cano Pavón
1Department of Analytical Chemistry, Faculty of Sciences, University of Málaga, 29071 Málaga, Spain. fsanchezr@uma.es
Abstract:
The determination of noble metals in environmental samples is of increasing importance. Palladium is often employed as a catalyst in chemical industry and is also used with platinum and rhodium in motor car catalytic converters which might cause environmental pollution problems. Two different sorbents for palladium preconcentration in different samples were investigated: silica gel functionalized with 1,5-bis(di-2-pyridyl)methylene tbiocarbohydrazide (DPTH-gel) and [1,5-Bis(2-pyridyl)-3-sulphophenyI methylene thiocarbonohydrazide (PSTH) immobilised on an anion-exchange resin (Dowex lx8-200)]. The sorbents were tested in a micro-column, placed in the auto-sampler arm, at the flow rate 2.8 mL min(-1). Elution was performed with 4 M HCl and 4 M HNO3, respectively. Satisfactory results were obtained for two sorbents.
Related Concept Videos
Sample Preparation for Analysis: Overview
Bulk or large solid samples are typically reduced in size using grinding, crushing, or milling techniques to increase the...
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...