Related Experiment Video
Updated: Jul 11, 2026

10:00
Assaying DNA Damage in Hippocampal Neurons Using the Comet Assay
Published on: December 19, 2012
Comet encke: radar detection of nucleus
Summary
Radar observations detected Comet Encke
Area of Science:
- Planetary Science
- Cometary Nucleus Research
- Radio Astronomy
Background:
- Periodic comet Encke is a subject of interest for understanding cometary nuclei.
- Previous studies have relied on indirect methods to estimate nucleus size.
Purpose of the Study:
- To determine the size of Comet Encke's nucleus using radar observations.
- To refine estimates of cometary nucleus dimensions.
Main Methods:
- Utilized the Arecibo Observatory's radar system operating at a 12.6-centimeter wavelength.
- Analyzed radar echoes in a specific circular polarization to infer nucleus properties.
Main Results:
- Detected the nucleus of Comet Encke.
- Measured a radar cross section of 1.1 +/- 0.7 square kilometers.
- Estimated the nucleus radius to be 1.5(+2.3)(-1.0) kilometers, with uncertainties dependent on scattering models.
Conclusions:
- Provided a radar-derived estimate for the radius of Comet Encke's nucleus.
- Highlighted the impact of scattering models and nucleus rotation on radius estimation.
- Acknowledged potential for the true radius to fall outside the calculated range due to model limitations.
Related Concept Videos
NMR Spectrometers: Overview
NMR spectrometers consist of a strong magnet, a radiofrequency transmitter, and a detector attached to a computer console for recording spectra of samples containing NMR-active nuclei. In first-generation NMR instruments called continuous-wave spectrometers, the resonance frequencies of the nuclei are determined by frequency-sweep or field-sweep methods. The magnetic field strength is fixed and the rf signal is swept in the former, while the radiofrequency signal is fixed and the magnetic field...
Gas Chromatography: Types of Detectors-II
In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
Atomic Emission Spectroscopy: Instrumentation
The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers. Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
Momentum And Radiation Pressure
An object absorbing an electromagnetic wave would experience a force in the direction of propagation of the wave. This force occurs because electromagnetic waves contain and transport momentum. The force accounts for the wave's radiation pressure exerted on the object. Maxwell's prediction was confirmed in 1903 by Nichols and Hull by precisely measuring radiation pressures with a torsion balance. The measuring instrument had mirrors suspended from a fiber kept inside a glass container. Nichols...
Atomic Nuclei: Magnetic Resonance
The number of nuclear spins aligned in the lower energy state is slightly greater than those in the higher energy state. In the presence of an external magnetic field, as the spins precess at the Larmor frequency, the excess population results in a net magnetization oriented along the z axis. When a pulse or a short burst of radio waves at the Larmor frequency is applied along the x axis, the coupling of frequencies causes resonance and flips the nuclear spins of the excess population from the...
Atomic Emission Spectroscopy: Interference
In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...

