Spectroscopic imaging with volume selection by unpaired adiabatic pi pulses: theory and application
Julien Valette1, Jang-Yeon Park, Olli Gröhn
1Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, 2021 Sixth Street SE, Minneapolis, MN 55455, USA. julien@cmrr.umn.edu
Abstract:
In NMR spectroscopy, volume selection can be advantageously achieved using adiabatic pi pulses, which enable high bandwidth and B(1) insensitivity. In order to avoid the generation of non-linear phase profiles and the subsequent signal loss caused by incoherent averaging, adiabatic pi pulses are usually used in pairs for volume selection in each spatial dimension. Alternatively, when performing spectroscopic imaging (SI), a high enough spatial resolution results in negligible phase dispersion within each pixel. This allows using only one pulse per selected spatial dimension, resulting in a reduced echo-time and reduced power deposition. In this work, the feasibility of such an approach is explored theoretically and numerically, allowing the derivation of explicit conditions to obtain SI images without artifact. Adequate spatial and spectral post-processing procedures are described to compensate for the effect of non-linear phase profiles. These developments are applied to SI in the rat brain at 9.4 T, using a new adiabatic sequence named Pseudo-LASER.
Related Concept Videos
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
Applications of IR Spectroscopy: Overview
IR Spectroscopy: Molecular Vibration Overview
Stretching vibrations are vibrational motions that occur along the bond line, changing the bond length or distance between two bonded atoms. They are further distinguished as symmetric or asymmetric. In symmetric stretching, the...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.