Related Experiment Video
Updated: Jul 11, 2026

Automated 90Sr Separation and Preconcentration in a Lab-on-Valve System at Ppq Level
Published on: June 6, 2018
Usefulness of the simultaneous bioassay analysis method used for an intake estimation of a radionuclide
1Korea Atomic Energy Research Institute, PO Box 105, Yuseong-gu, Daejeon, Republic of Korea. jilee2@kaeri.re.kr
Abstract:
An intake of a radionuclide is estimated based on bioassay measurement data obtained by an in vivo or an in vitro method. Often the intake estimates from one bioassay analysis are considerably different from other results. For better estimates, a simultaneous or combined analysis of measurement data from different bioassay methods is attempted. In this study, the usefulness of a simultaneous bioassay analysis was investigated by using the IDEAS/IAEA intercomparison exercise data and the Individual Monitoring of an Internal Exposure computer code. Tests were made for whole-body counting and urine assay against an acute inhalation of types M and S 60Co particles with various activity median aerodynamic diameter (AMAD). The data set excluding rogue data as well as all the available data were used in this study. The best estimated intake was evaluated based on the best-fit time of an intake determined by minimizing the mean relative deviation Dr. In the case of the whole-body and urine bioassay by using the data excluding some rogue data, the smallest Dr appears at 0.1 and 10 microm of AMAD, respectively, which are different from those estimated by using all the available data. In the case of the simultaneous analysis, it appears at 20 microm of AMAD, which is the same as that estimated by using all the available data. Supposing that monitoring data of a good quality is available, it is expected that the application of a simultaneous analysis to different bioassay methods can provide not only better estimates of an intake but also insights into the validity of the models and parameters used in an interpretation.
More Related Videos
Related Concept Videos
Measurement of Bioavailability: Pharmacokinetic Methods
Bioavailability Study Design: Single Versus Multiple Dose Studies
Methods for Studying Drug Absorption: In situ
The Doluisio method involves perfusing a prepared segment of a rat's small intestine with a solution of radiolabeled drug and a non-absorbable marker. This helps to differentiate between absorbed and non-absorbed drug concentrations. The intestinal segment is connected at both ends using tubing and syringes,...
One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation
On...
Measurement of Bioavailability: Pharmacodynamic Methods
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
![Technical Aspect of the Automated Synthesis and Real-Time Kinetic Evaluation of [11C]SNAP-7941](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F59557.jpg&w=3840&q=50)
