Spectral quality control in motion-corrupted single-voxel J-difference editing scans: an interleaved navigator
P K Bhattacharyya1, M J Lowe, M D Phillips
1Division of Radiology, Cleveland Clinic, Foundation, Cleveland, Ohio 44195, USA. bhattap@ccf.org
Abstract:
Motion has an adverse effect on spectral quality and needs to be properly identified in MR spectroscopy (MRS) scans. Spectral subtraction-based techniques like J-difference editing are prone to be affected more by subject motion where motion can result in false peaks or inefficient subtraction of peaks. Introducing a water signal-based interleaved navigator scan in the MEGA point-resolved spectroscopy (MEGA-PRESS) sequence and acquiring data on a shot-by-shot basis, subject motion inside a scanner was tracked and motion-corrupted data were identified and excluded from the dataset. Performing a gamma-aminobutyric acid (GABA) editing scan at the occipital cortex, it was possible to retrieve a properly edited GABA spectrum from a dataset otherwise to be discarded due to motion. This study demonstrates the importance of independent motion assessment in J-difference editing.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
NMR Spectrometers: Resolution and Error Correction
X-ray Imaging
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...