Related Experiment Video
Updated: Jul 11, 2026

A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
Solid-phase extraction combined with dispersive liquid-liquid microextraction-ultra preconcentration of chlorophenols
Nazir Fattahi1, Soheila Samadi, Yaghoub Assadi
1Department of Analytical Chemistry, Faculty of Chemistry, Electroanalytical Chemistry Research Center, Iran University of Science and Technology, Tehran, Iran.
Abstract:
The solid-phase extraction (SPE) joined with the dispersive liquid-liquid microextraction (DLLME) has been developed as an ultra preconcentration technique for the determination of chlorophenols in water samples. Chlorophenols (CPs) were employed as model compounds to assess the extraction procedure and were determined by gas chromatography-electron-capture detection (GC-ECD). In solid-phase extraction-dispersive liquid-liquid microextraction (SPE-DLLME), CPs were adsorbed from a large volume of aqueous samples (100 mL) into 100 mg functionalized styrene-divinylbenzene polymer (PPL) sorbent. After the elution of the desired compounds from the sorbent by using acetone, DLLME technique was performed on the obtained solution. Some important extraction parameters, such as sample solution flow rate, breakthrough volume, sample pH, type and volume of the elution solvent as well as the salt addition, were studied and optimized. The new method (SPE-DLLME) provided an ultra enrichment factor (4390-17,870) for 19 CPs. The calibration graphs were linear in the range of 0.001-20 microg L(-1) and the limits of detection (LODs) ranged from 0.0005 to 0.1 microg L(-1). The relative standard deviations (RSDs, for 10.0 microg L(-1) of MCPs, 5.00 microg L(-1) of DCPs, 0.200 microg L(-1) of TCPs, 0.100 microg L(-1) of TeCPs and PCP) with and without the internal standard varied from 1.1 to 6.4% (n=7) and 2.5-9.7% (n=7), respectively. The relative recoveries of the well, tap and river water samples, spiked with different levels of CPs, were 71-110%, 73-115% and 88-121%, respectively.
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
Extraction: Advanced Methods
High-Performance Liquid Chromatography: Instrumentation
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Ion-Exchange Chromatography