Related Experiment Video
Updated: Jul 11, 2026

Asymmetrical Flow Field-Flow Fractionation for Sizing of Gold Nanoparticles in Suspension
Published on: September 11, 2020
Novel approaches to analysis by flow injection gradient titration.
Marzena Wójtowicz1, Joanna Kozak, Paweł Kościelniak
1Department of Analytical Chemistry, Faculty of Chemistry, Jagiellonian University, 30-060 Kraków, Poland.
Two new flow injection gradient titration methods, multi-point single-line (MP-SL) and single-point multi-line (SP-ML), simplify titrations using a single standard solution. These techniques offer precise and accurate acid-base analysis, including in vinegar samples.
Area of Science:
- Analytical Chemistry
- Spectrophotometry
- Titration Techniques
Background:
- Traditional titration methods can be time-consuming and require multiple standard solutions.
- Developing efficient and accurate analytical procedures is crucial for chemical analysis.
- Flow injection analysis offers potential for automated and rapid chemical measurements.
Purpose of the Study:
- To introduce two novel flow injection gradient titration procedures: multi-point single-line (MP-SL) and single-point multi-line (SP-ML).
- To demonstrate the utility of these methods using a single stock standard solution for constructing calibration graphs.
- To evaluate the precision and accuracy of the proposed methods for acid-base titrations.
Main Methods:
- MP-SL method: Calibration graph constructed from standard solutions generated in a reservoir and injected into the titrant.
- SP-ML method: Standard solution and sample injected into the titrant stream from multiple loops of different capacities.
- Spectrophotometric acid-base titration of hydrochloric and acetic acids using bromothymol blue and phenolphthalein indicators with sodium hydroxide titrant.
Main Results:
- MP-SL procedure achieved precision <1.8% RSD and accuracy <3.0% RE for hydrochloric acid (0.0031-0.0631 mol L⁻¹).
- SP-ML procedure achieved precision <2.5% RSD and accuracy <5.4% RE for acetic acid (0.1680-1.7600 mol L⁻¹).
- Both methods demonstrated feasibility in determining total acidity in vinegar samples with high precision (<0.5% RSD for MP-SL, <2.9% RSD for SP-ML).
Conclusions:
- The proposed MP-SL and SP-ML methods are effective for flow injection gradient titration using a single standard solution.
- These novel procedures offer reliable and accurate results for acid-base titrations across various concentration ranges.
- The methods are practical for real-world applications, such as analyzing acidity in food products like vinegar.
More Related Videos
Related Concept Videos
Titrimetric Methods: Types and Commonly Used Strategies
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Classification of Titrimetric Analysis Based on Reaction Types
Titrations between an acid and a base lead to neutralization reactions that form...
Fast Reactions
Controlled-Current Coulometry: Coulometric Titration
The fundamental requirements for coulometric titrations are (1) 100% efficiency in the reagent-generating electrode reaction and (2) a stoichiometric and preferably rapid reaction between the generated...
Precipitation Titration: Overview
A precipitation titration curve demonstrates the change in concentration of the titrant or analyte upon adding the...

