Abstract:
The presented paper deals with a new methodology for direct determination of propranolol in human plasma. The methodology described is based on sequential injection analysis technique (SIA) coupled with solid phase extraction (SPE) column based on restricted access materials (RAM). Special RAM column containing 30 microm polymeric material-N-vinylacetamide copolymer was integrated into the sequential injection manifold. SIA-RAM system was used for selective retention of propranolol, while the plasma matrix components were eluted with two weak organic solutions to waste. Due to the acid-basic and polarity properties of propranolol molecule and principles of reversed-phase chromatography, it was possible to retain propranolol on the N-vinylacetamide copolymer sorbent (Shodex MSpak PK-2A 30 microm (2 mm x 10 mm)). Centrifuged plasma samples were aspirated into the system and loaded onto the column using acetonitrile-water (5:95, v/v), pH 11.00, adjusted by triethylamine. The analyte was retained on the column while proteins contained in the sample were removed to waste. Interfering endogenous substances complicating detection were washed out by acetonitrile-water (15:85), pH 11.00 in the next step. The extracted analyte was eluted by means of tetrahydrofuran-water (25:75), pH 11.00 to the fluorescence detector (emission filter 385 nm). The whole procedure comprising sample pre-treatment, analyte detection and column reconditioning took about 15 min. The recoveries of propranolol from undiluted plasma were in the range 96.2-97.8% for three concentration levels of analyte. The proposed SIA-RAM method has been applied for direct determination of propranolol in human plasma.
More Related Videos
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
06:25Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns
Published on: April 26, 2016
Related Concept Videos
High-Performance Liquid Chromatography: Elution Process
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Principles Of Column Chromatography