Matrix effects in thermal lens spectrometry: influence of salts, surfactants, polymers and solvent mixtures
Related Experiment Video
Updated: Jul 11, 2026

Characterization of Synthetic Polymers via Matrix Assisted Laser Desorption Ionization Time of Flight (MALDI-TOF) Mass Spectrometry
Published on: June 10, 2018
1Laboratoire des Sciences Analytiques - UMR 5180, Université Claude Bernard-Lyon 1, Domaine Scientifique de la Doua, Bâtiment CPE-308D, 69622 Villeurbanne Cedex, France. j.georges@cpe.fr
Abstract:
In this paper, we present an overall view of the matrix effects that can change or alter the signal in thermal lens spectrometry and we report the main works published in this field. The addition of salts, surfactants and polymers in aqueous solutions or the use of solvent mixtures is often needed in a variety of applications either to enhance the sensitivity of the thermal lens method or more generally because such media are required in the separation process prior to thermal lens detection. In most cases, matrix effects result in small changes in the thermo-optical properties of the solution and small signal variations. However, most important signal alterations can arise from the Soret effect. In binary mixtures as well as in solutions with macromolecular species which are initially homogeneous, the temperature gradient will induce the migration of molecules and the formation of a concentration gradient. This results in the formation of a concentration-dependent refractive index gradient which adds to the temperature-dependent refractive index gradient and contributes to the formation of a new signal. This effect can seriously alter the analytical signal and lead to erroneous interpretation of the experimental data. In contrast, time-resolved measurements can help in separating both signal components and have allowed to derive mass-diffusion times and mass-diffusion coefficients for a variety of micelles and polymers.
Related Concept Videos
Atomic Spectroscopy: Effects of Temperature
At thermal equilibrium, the relative populations of excited and ground state atoms can be estimated using the Maxwell–Boltzmann distribution. For example, an increase in temperature from...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Emission Spectroscopy: Interference
Ionic Strength: Effects on Chemical Equilibria
In this solution, the primary cation—the calcium...
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...