A Strategy for Sensitive, Large Scale Quantitative Metabolomics
Published on: May 27, 2014
Multiple testing issues in discriminating compound-related peaks and chromatograms from high frequency noise, spikes
Stephen O Nyangoma1, Antoine A H C van Kampen, Theo H Reijmers
1University of Birmingham.
Abstract:
Liquid Chromatography--Mass Spectrometry (LC-MS) is a powerful method for sensitive detection and quantification of proteins and peptides in complex biological fluids like serum. LC-MS produces complex data sets, consisting of some hundreds of millions of data points per sample at a resolution of 0.1 amu in the m/z domain and 7000 data points in the time domain. However, the detection of the lower abundance proteins from this data is hampered by the presence of artefacts, such as high frequency noise and spikes. Moreover, not all of the tens of thousands of the chromatograms produced per sample are relevant for the pursuit of the biomarkers. Thus in analysing the LC-MS data, two critical pre-processing issues arise. Which of the thousands of the: 1. chromatograms per sample are relevant for the detection of the biomarkers?, and 2. signals per chromatogram are truly compound-related? Each of these issues involves assessing the significance (deviation from noise) of multiple observations and the issue of multiple comparisons arises. Current methods disregard the multiplicity and provide no concrete threshold for significance. However, with such procedures, the probability of one or more false-positives is high as the number of tests to be performed is large, and must be controlled. Realizing that the cut-offs for declaring a chromatogram (or a signal) to be compound-related can hugely influence which proteins are detected, it seems natural to define thresholds that are neither arbitrary nor subjective. We suggest the choice of thresholds guided by the critical aim of controlling the False Discovery Rate (FDR) in multiple hypotheses testing for significance over a large set of features produced per sample. This involves the use of the regression diagnostics to characterize the signals of a chromatogram (e.g. as outliers or influential) and to suggest suitable tests statistics for the multiple testing procedures (MTP) for discriminating noise and spikes from true signals. The role of the Generalized Linear Models (GLM) in this MTP is investigated. The method is applied to LC-MS datasets from trypsin-digested serum spiked with varying levels of horse heart cytochrome C (cytoc).
More Related Videos
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
Related Concept Videos
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
High-Performance Liquid Chromatography: Types of Detectors
High-Resolution Mass Spectrometry (HRMS)
Tandem Mass Spectrometry