Related Experiment Video
Updated: Jul 11, 2026

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Rapid screening of anabolic steroids in urine by reactive desorption electrospray ionization
Guangming Huang1, Hao Chen, Xinrong Zhang
1Department of Chemistry, Tsinghua University, Beijing 100084, China.
Abstract:
Fast screening for anabolic steroids in whole urine is achieved by combining reactive desorption electrospray ionization (reactive DESI) and tandem mass spectrometry. Spray solutions containing hydroxylamine allow heterogeneous reactions of hydroxylamine with the carbonyl group of the steroids during the ionization process. Seven steroids, including a glycosteroid, were examined. The ion/molecule reaction adduct and the oxime formed via its dehydration were observed using reactive DESI; the protonated and sodiated forms of the ionized steroid were also observed both in reactive DESI and in DESI performed without the added hydroxylamine reagent. Paper, glass, and polytetrafluoroethylene were tested as sample substrates, but the glycosteroid was ionized intact without hydrolysis only from polytetrafluoroethylene. Limits of detection for the pure compounds were less than 1 ng, dynamic ranges were typically 2 orders of magnitude, and analysis times were just a few seconds. Concentration levels of ketosteroids in raw urine relevant to screening for sports doping (approximately 20 ng/mL) can be reached using a simple solid-phase microextraction (SPME) preconcentration step. Reactive DESI provided significant improvements in ionization efficiency of these steroids in raw undiluted urine as compared to conventional DESI; suppression effects due to the sample matrix were minimal and the urine matrix had no deleterious effect on steroid detection limits. Tandem mass spectrometry provided confirmation of analyte identification in this rapid screening process.
More Related Videos
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
08:41Integration of Miniaturized Solid Phase Extraction and LC-MS/MS Detection of 3-Nitrotyrosine in Human Urine for Clinical Applications
Published on: July 14, 2017
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
High-Performance Liquid Chromatography: Types of Detectors
Ion-Exchange Chromatography