Fast gas chromatography for pesticide residues analysis using analyte protectants
Michal Kirchner1, Renáta Húsková, Eva Matisová
1Institute of Analytical Chemistry, Faculty of Chemical and Food Technology, Slovak University of Technology, Radlinskeho 9, SK-812 37 Bratislava, Slovakia.
Abstract:
Fast GC-MS with narrow-bore columns combined with effective sample preparation technique (QuEChERS method) was used for evaluation of various calibration approaches in pesticide residues analysis. In order to compare the performance of analyte protectants (APs) with matrix-matched standards calibration curves of selected pesticides were searched in terms of linearity of responses, repeatability of measurements and reached limit of quantifications utilizing the following calibration standards in the concentration range 1-500 ng mL(-1)(the equivalent sample concentration 1-500 microg kg(-1)): in neat solvent (acetonitrile) with/without addition of APs, matrix-matched standards with/without addition of APs. For APs results are in a good agreement with matrix-matched standards. To evaluate errors of determination of concentration synthetic samples at concentration level of pesticides 50 ng mL(-1) (50 microg kg(-1)) were analyzed and quantified using the above given standards. For less troublesome pesticides very good estimation of concentration was obtained utilizing APs, while for more troublesome pesticides such as methidathion, malathion, phosalone and deltamethrin significant overestimation reaching up to 80% occurred. According to presented results APs can be advantegously used for "easy" pesticides determination. For "difficult" pesticides an alternative calibration approach is required for samples potentially violating MRLs. An example of real sample measurement is shown. In this paper also the use of internal standards (triphenylphosphate (TPP) and heptachlor (HEPT)) for peak areas normalization is discussed in terms of repeatability of measurements and quantitative data obtained. TPP normalization provided slightly better results than the use of absolute peak areas measurements on the contrary to HEPT.
More Related Videos
05:20Determination of 45 Pesticides in Avocado Varieties by the QuEChERS Method and Gas Chromatography-Tandem Mass Spectrometry
Published on: December 8, 2023
04:17Analysis of Organochlorine Pesticides in a Soil Sample by a Modified QuEChERS Approach Using Ammonium Formate
Published on: January 20, 2023
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Detectors-II
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...