Decreased Body Temperature01:29

Decreased Body Temperature

A decreased body temperature can occur in patients with hypothermia and frostbite. Heat loss with extended cold exposure overpowers the body's ability to create heat, resulting in hypothermia. Core temperature readings help classify hypothermia. Mild hypothermia is temperatures between 32 °C (89.6 °F) and 35°C (95 °F) and is caused by impaired thermoregulation. Moderate hypothermia is temperatures between 28 C (82.4 °F) and 32 °C (89.6 °F) caused by sustained extreme cold exposure, and severe...
Temperature Measurement Sites01:14

Temperature Measurement Sites

A thermometer measures body temperature. The common sites for measuring body temperature are the oral cavity, axillary region, temporal artery, and skin surface, such as the forehead, abdomen, and axilla. True core body temperature is assessed in the rectum, tympanic membrane, pulmonary artery, esophagus, and urinary bladder.
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature01:13

Equipments Used to Measure Body Temperature

Body temperature can be assessed using various devices and measured in Celsius or Fahrenheit.
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Fetal Circulation01:14

Fetal Circulation

Fetal circulation is a unique system that facilitates the exchange of gases, nutrients, and waste products between the developing fetus and the mother. This intricate process takes place through a special organ called the placenta.
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...
Assessing Body Temperature - Temporal Artery01:19

Assessing Body Temperature - Temporal Artery

Here is a stepwise guide to assessing the body temperature at the temporal artery using a temporal artery thermometer
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.  
Step 3: Assess the patient's forehead...
Assessing Body Temperature - Rectal01:27

Assessing Body Temperature - Rectal

Rectal temperature measurement is considered the most precise method for assessing core body temperature and typically registers higher than oral temperature. For adults, the rectal thermometer should be inserted 1 to 1.5 inches into the rectum to obtain the most accurate reading.
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Risk Factors for Reintervention in Children with Subvalvular Aortic Stenosis: A 20-Year Single-Center Study.

Journal of cardiovascular development and disease·2025
Same author

The Fontan Enigma: Ventilating Between Lows and Highs.

Paediatric anaesthesia·2025
Same author

Infantile Dilated Cardiomyopathy in Alström Syndrome.

Cureus·2025
Same author

Case report: Personalized triple phage-antibiotic combination therapy to rescue necrotizing fasciitis caused by Panton-Valentine leukocidin-producing MRSA in a 12-year-old boy.

Frontiers in cellular and infection microbiology·2024
Same author

Failure to Rescue Pediatric Recipients of Living Donor Liver Transplantation: A Single-Center Study of Technical Complications in 500 Primary Grafts.

Pediatric transplantation·2024
Same author

Intravenous lipid emulsion for a life-threatening prothipendyl intoxication.

BMJ case reports·2024

Related Experiment Video

Updated: Jul 10, 2026

Assessment and Evaluation of the High Risk Neonate: The NICU Network Neurobehavioral Scale
19:15

Assessment and Evaluation of the High Risk Neonate: The NICU Network Neurobehavioral Scale

Published on: August 25, 2014

Torch on a baby's tummy

Pierre Demaret1, Thierry Detaille

  • 1Paediatric Intensive Care Unit, Saint-Luc University Clinics, Université Catholique de Louvain, Brussels, Belgium. pietdem@yahoo.fr

Lancet (London, England)
|October 16, 2007
PubMed
Summary

No abstract available in PubMed .

More Related Videos

A Modified Sonographic Algorithm for Image Acquisition in Life-Threatening Emergencies in the Critically Ill Newborn
11:27

A Modified Sonographic Algorithm for Image Acquisition in Life-Threatening Emergencies in the Critically Ill Newborn

Published on: April 7, 2023

Related Experiment Videos

Last Updated: Jul 10, 2026

Assessment and Evaluation of the High Risk Neonate: The NICU Network Neurobehavioral Scale
19:15

Assessment and Evaluation of the High Risk Neonate: The NICU Network Neurobehavioral Scale

Published on: August 25, 2014

A Modified Sonographic Algorithm for Image Acquisition in Life-Threatening Emergencies in the Critically Ill Newborn
11:27

A Modified Sonographic Algorithm for Image Acquisition in Life-Threatening Emergencies in the Critically Ill Newborn

Published on: April 7, 2023