Objective:
The aim of this study was to compare the bond strengths of 2 types of dual-cured luting agents used for cementation of 4 different fiber-reinforced composite (FRC) posts by using a push-out test and to evaluate the failure modes of these systems.
Study Design:
Eighty human maxillary central incisors were divided into 8 groups (n = 10), decoronated, and roots filled and restored with one of the following post systems: groups 1 to 4: translucent quartz FRC posts; groups 5 and 6: opaque glass FRC post; and groups 7 and 8: individually formed electrical glass fiber post. Cementation was performed with 2 types of dual-polymerizing resin luting agents: Variolink II (groups 1, 3, 5, and 7) and a new self-adhesive resin cement, RelyX Unicem (groups 2, 4, 6, and 8). Slices with a thickness of 1.00 +/- 0.05 mm were prepared from the coronal third of each root by using a low-speed saw. Push-out tests were performed at a crosshead speed of 1 mm/min by using a universal testing machine, and the data was statistically analyzed (analysis of variance [ANOVA] and Duncan tests; P < .05). Fracture modes were evaluated at original magnification x40.
Results:
Micro push-out bond strengths were significantly affected by the type of luting agent and the type of post (P < .05, 2-way ANOVA). A significant difference was found among the groups (1-way ANOVA, P < .05). Fiber-reinforced composite posts luted with Variolink II showed higher bond strengths, and the groups ordered as 5, 1, 3, 7, 6, 2, 4, and 8, with the values (MPa, mean +/- SD): 13.80 +/- 5.00, 13.77 +/- 3.78, 12.20 +/- 4.79, 9.39 +/- 2.48, 9.21 +/- 7.76, 7.25 +/- 1.56, 3.89 +/- 4.41, and 3.77 +/- 1.20, respectively. Adhesive failures between dentin and cement were observed more than cohesive failures in cement or post.
Conclusions:
Push-out bond strengths can be affected by luting agent and post type. Variolink II and fiber post combinations resulted in high bond strength values.
Related Concept Videos
Bonding and Strength of Aggregate
Fiber Reinforced Concrete
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in ASTM C...
Posttensioned Masonry Walls
Post-tensioned masonry walls use high-strength steel rods or flexible tendons to enhance the strength and efficiency of masonry structures. These elements are securely anchored to the foundation and extend vertically either within the cores of the masonry units or between the masonry wythes. The construction process involves building the wall with these tensioning elements in place and allowing the mortar to fully cure.
Following the curing process, the tensioning begins. Steel rods are...
Reinforcements in Concrete
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen also...