A Novel Non-invasive Method for the Detection of Elevated Intra-compartmental Pressures of the Leg
Published on: May 31, 2019
Ultrasound-guided noninvasive measurement of a patient's central venous pressure
Vikram Aggarwal1, Aniruddha Chatterjee, Yoonju Cho
1Dept. of Biomed. Eng., Johns Hopkins Univ., Baltimore, MD, USA. vaggarwal@jhu.edu
Abstract:
Central venous pressure (CVP) is an important physiological parameter, the correct measure of which is a clinically relevant diagnostic tool for heart failure patients. A current challenge for physicians, however, is to obtain a quick and accurate measure of a patient's CVP in a manner that poses minimum discomfort. Current approaches for measuring CVP involve invasive methods such as threading a central venous catheter along a major vein, or tedious physical exams that require physicians to grossly estimate the measurement. Our solution proposes a novel noninvasive method to estimate central venous pressure using ultrasound-guided surface pressure measurement. Specifically, our device works in conjunction with an ultrasound machine and probe that is used to visualize the interior jugular (IJ) vein below the surface of the skin on a patient's neck. Once the interior jugular vein is located, our device detects the pressure on the skin required to collapse the IJ and correlates this value to a central venous pressure reading reported to the operator. This quick and noninvasive measurement is suitable for emergency situations or primary care settings where rapid diagnosis of a patient's CVP is required, and prevents the need for further invasive and costly procedures. The measurement procedure is also simple enough to be performed by operators without extensive medical training.
Related Concept Videos
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Parentral Nutrition: Centeral and Peripheral Parental Nutrition
PN can be administered through two primary routes:
1. Central Parenteral Nutrition (CPN):
CPN involves delivering a high concentration of nutrients through a large vein. This is typically achieved using a Peripherally Inserted Central Catheter (PICC) or,...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement