Related Experiment Video
Updated: Jul 10, 2026

Continuous Telemetric In Utero Tracheal Pressure Measurements in Fetal Lambs
Published on: December 22, 2023
Interface pressure monitoring for a secured instrumented childbirth
C Ramon1, C Gehin, P M Schmitt
1Biomed. Microsensors Dept., Nat. Inst. of Appl. Sci., Villeurbanne, France. carolina.ramon-zarate@insa-lyon.fr
Complications in forceps deliveries are rare but their consequences might be dramatics. This situation could be avoided if the obstetrician knows the information concerning symmetry of the obstetrical forceps position on the fetal head and the related interface pressure. Indeed, forceps delivery is an emergency gesture which is normally not expected. Our purpose is to determinate relevant parameters for a fast decision-making without any danger for the fetus. We have developed a new interface pressure measurement system in order to study pressure distribution of human body whatever its support (forceps, chair, bed...). This method has been adapted to measure the interface pressure between the fetal head and the forceps. This new system also provides information of forceps position symmetries. The aims of this system are: first, to prevent instrumented delivery accidents. Secondly, to provide a safe training of forceps technique. This paper presents results about experiments performed on phantoms of fetal head. Different forceps positions on phantom have been tested according to the classification of forceps application as per A.C.O.G 1981 (revised in 1991). These experiments have lead to the definition of relevant parameters in order to help the physician to validate the forceps positions before extraction.
Complications in forceps deliveries are rare but their consequences might be dramatics. This situation could be avoided if the obstetrician knows the information concerning symmetry of the obstetrical forceps position on the fetal head and the related interface pressure. Indeed, forceps delivery is an emergency gesture which is normally not expected. Our purpose is to determinate relevant parameters for a fast decision-making without any danger for the fetus. We have developed a new interface pressure measurement system in order to study pressure distribution of human body whatever its support (forceps, chair, bed...). This method has been adapted to measure the interface pressure between the fetal head and the forceps. This new system also provides information of forceps position symmetries. The aims of this system are: first, to prevent instrumented delivery accidents. Secondly, to provide a safe training of forceps technique. This paper presents results about experiments performed on phantoms of fetal head. Different forceps positions on phantom have been tested according to the classification of forceps application as per A.C.O.G 1981 (revised in 1991). These experiments have lead to the definition of relevant parameters in order to help the physician to validate the forceps positions before extraction.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)
