Related Experiment Video
Updated: Jul 10, 2026

A Synthetic Methodology for Preparing Impregnated and Grafted Amine-Based Silica Composites for Carbon Capture
Published on: September 29, 2023
Impact of sulfur oxides on mercury capture by activated carbon
Albert A Presto1, Evan J Granite
1National Energy Technology Laboratory, United States Department of Energy, P.O. Box 10940, MS 58-103A, Pittsburgh, Pennsylvania 15236-0940, USA.
Abstract:
Recent field tests of mercury removal with activated carbon injection (ACI) have revealed that mercury capture is limited in flue gases containing high concentrations of sulfur oxides (SOx). In order to gain a more complete understanding of the impact of SOx on ACl, mercury capture was tested under varying conditions of SO2 and SO3 concentrations using a packed bed reactor and simulated flue gas (SFG). The final mercury content of the activated carbons is independent of the SO2 concentration in the SFG, but the presence of SO3 inhibits mercury capture even at the lowest concentration tested (20 ppm). The mercury removal capacity decreases as the sulfur content of the used activated carbons increases from 1 to 10%. In one extreme case, an activated carbon with 10% sulfur, prepared by H2SO4 impregnation, shows almost no mercury capacity. The results suggest that mercury and sulfur oxides are in competition for the same binding sites on the carbon surface.
Related Concept Videos
The Sulfur Cycle
Microbes and the Sulfur Cycle
Sulfur Assimilation
Acid Mine Drainage
Electrophilic Aromatic Substitution: Sulfonation of Benzene
The Scientific Method