Related Experiment Video
Updated: Jul 10, 2026

Synthesis of Soft Polysiloxane-urea Elastomers for Intraocular Lens Application
Published on: March 8, 2019
The effect of lens wear on refractive index of conventional hydrogel and silicone-hydrogel contact lenses: a
1Center of Physics (Optometry), School of Sciences, University of Minho, Portugal. mlira@fisica.uminho.pt
Purpose:
The purpose of this work was to evaluate the ability of four silicone-hydrogel contact lenses (galyfilcon A, balafilcon A, lotrafilcon A and lotrafilcon B) to retain their equilibrium water content before and after wear, through measurements of refractive index and compare with that of a conventional disposable hydrogel contact lens (etafilcon A).
Methods:
The refractive indices of 115 contact lenses were measured using an automated refractometer (CLR 12-70, Index Instruments, Cambridge, U.K.) before and after a schedule of daily wear by 58 patients for 30 days in the case of silicone-hydrogel lenses and 15 days for the conventional contact lenses.
Results:
In the silicone-hydrogel contact lenses the changes on the refractive indices were not statistically significant, however after being worn the refractive index of the conventional etalfilcon A hydrogel contact lens increased significantly (p<0.001).
Conclusion:
The results presented here show that after being worn the silicone-hydrogel contact lens, show more capacity to retain or to reach their initial equilibrium water content than conventional hydrogel contact lenses. This suggests that the silicone-hydrogel contact lenses are less susceptible to spoilation over time maintaining its biocompatibility and contributing to the clinical success of lens performance.