Related Experiment Video
Updated: Jul 10, 2026

Use of MRI-ultrasound Fusion to Achieve Targeted Prostate Biopsy
Published on: April 9, 2019
Computed tomography-ultrasound fusion brachytherapy: description and evolution of the technique
1Department of Radiation Oncology, Radiation Medical Group, Inc., San Diego, CA 92101, USA. dfuller@rmgmed.com
Purpose:
In this manuscript, we describe our computed tomography (CT)-ultrasound (US) fusion prostate brachytherapy method and report the updated dosimetry result and trend.
Methods And Materials:
This cohort of 132 consecutive patients received CT-US fusion prostate brachytherapy from the first author (DBF) from December 2002 to August 2006. The technique consists of a hybrid preplanned and intraoperative dynamic dosimetry method, which initially delivers a standard preplanned source distribution, and then uses interval CT-based source identification dosimetry, fused to an identically spaced intraoperative US volume study series, to direct remedial sources that correct initial dosimetry deficiencies.
Results:
The median and minimum prostate Day 0 prostate volume of interest receiving 100% of prescribed dose (V(100)) results in this patient cohort measured 98.26% and 92.61%, respectively, with all Day 0 prostate dose received by 90% of the volume of interest (D(90)) results exceeding 100% of the prescribed dose, and the maximum Day 0 prostate D(90) value measuring 128% of the prescribed dose. During the period of this analysis, a trend to the decreased quantity of dynamic remedial millicuries per case was identified, with the total sources decreasing from 116% to 106% of the preplanned level, resulting in minimal V(100) and D(90) decreases, while continuing to exceed the minimum Day 0 dosimetry requirements.
Conclusions:
CT-US fusion dynamic prostate brachytherapy represents a consistent prostate brachytherapy dosimetry delivery mechanism, creating a tight lower and upper bound to the final Day 0 prostate V(100) and D(90) parameters. The practice and pitfalls of this technique are discussed in detail.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
