Related Experiment Video
Updated: Jul 10, 2026

An “All-laser” Endothelial Transplant
Published on: July 6, 2015
Glide insertion technique for donor cornea lenticule during Descemet's stripping automated endothelial keratoplasty
Jodhbir S Mehta1, Yong-Ming Por, Roger W Beuerman
1Singapore National Eye Centre, Yong Loo Lin School of Medicine, National University of Singapore, Singapore.
Abstract:
We describe a simple technique for inserting the donor corneal lenticule in Descemet's stripping automated endothelial keratoplasty. Unlike the standard insertion method, which requires folding the donor lenticule, this technique uses a modified intraocular lens (IOL) glide to guide the unfolded donor lenticule through the small incision with an intraocular forceps. This prevents significant endothelial trauma and surgical difficulties when the lenticule is unfolded. Additional endothelial protection is provided by an ophthalmic visco-surgical device on the IOL glide, which protects the donor endothelium from the corneal wound edge and prevents iris prolapse during insertion.