Fetal oxygen saturation after combined spinal-epidural labor analgesia: a case series

Brendan Carvalho1, Andrea J Fuller, Catherine Brummel

  • 1Department of Anesthesia, Stanford University School of Medicine, Stanford, CA 94305, USA. bcarvalho@stanford.edu

Fetal oxygen saturation (FSpo(2)) is an emerging technology for intrapartum fetal monitoring. We monitored FSpo(2) before and after combined spinal-epidural analgesia in 8 laboring women requesting neuraxial analgesia. Fetal heart rate (FHR) and FSpo(2) (using the Nellcor N400/FS14 system [Nellcor, Pleasanton, CA]) were recorded at baseline and every minute for 45 minutes after analgesia. We observed no significant changes in FSpo(2) after analgesia (mean DeltaFSpo(2) 2 +/- 7 %, P = 0.46). Fetal oxygen saturation at baseline and after analgesia was 53% +/- 9% and 51% +/- 8%, respectively. We observed no significant FHR changes or any fetal bradycardia following combined spinal-epidural analgesia.

Related Concept Videos

Local Anesthetics: Clinical Application as Epidural Anesthesia01:29

Local Anesthetics: Clinical Application as Epidural Anesthesia

Epidural anesthetics are administered in the fat-filled epidural space, the outermost part of the spinal canal. This technique is commonly employed for pain management and anesthesia during lower abdomen and pelvis surgeries or labor and delivery.
Since epidural anesthetics can be infused through an epidural catheter, all types of drugs, including short-acting ones, can be administered. Chloroprocaine and lidocaine are examples of short and long-duration anesthetics, respectively. Bupivacaine...
Local Anesthetics: Clinical Application as Spinal Anesthesia01:11

Local Anesthetics: Clinical Application as Spinal Anesthesia

Spinal anesthetics are given during lower abdomen and limb surgeries to block sensory and motor neurons. They are administered in the mid to low lumbar regions, primarily acting on the cauda equina's nerve roots. The blockade level depends on the local anesthetic (LA) concentration. Usually, low LA concentrations are sufficient to block sensory fibers, while only high LA concentrations block motor fibers. Other factors like injection volume and speed, the patient's posture, and the drug...
Pulse Oximetry01:24

Pulse Oximetry

Pulse oximetry, or SpO2, is a non-invasive method for continuously monitoring arterial oxygen saturation (SaO2). This procedure involves attaching a probe or sensor to the patient's fingertip, forehead, earlobe, or nose bridge. The sensor works by detecting changes in oxygen saturation levels through light signals generated by the oximeter and reflected by the pulsing blood under the probe.
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...