Quantitative Proteomics Using Reductive Dimethylation for Stable Isotope Labeling
Published on: July 1, 2014
Efficient identification and quantification of proteins using isotope-coded 1-(6-methylnicotinoyloxy)succinimides by
Hiroki Tsumoto1, Chie Murata, Naoki Miyata
1Research Institute of Pharmaceutical Sciences, Musashino University, Shinmachi Nishitokyo-shi, Tokyo 202-8585, Japan.
We describe a convenient and useful method for the identification and relative quantification of proteins using light and heavy reagents, 1-(6-methylnicotinoyloxy)succinimides (6-CH(3)-Nic-NHS and 6-CD(3)-Nic-NHS, respectively). This method is based on the chemical derivatization of amino groups of tryptic peptides with these reagents, i.e., the basic moiety of the reagents thus incorporated into both the N-terminal amino group and the epsilon-amino group of the lysine residue would improve the ionization efficiency of tryptic peptides. An increase in protein sequence coverage is achieved by derivatization with these reagents or by combination of mass values before and after derivatization. Since a combination of 6-CH(3)-Nic-NHS and d(3)-labeled reagent (6-CD(3)-Nic-NHS) generates a 3 Da mass difference per reaction site, the d(3)-labeled reagent shifts the mass values of d(0)-labeled peptides according to the number of reactive amino groups in the peptides. In the case of tryptic peptides, the mass values of C-terminal arginine and lysine peptides are shifted by 3 and 6 Da, respectively. Further, the 3 Da mass difference between 6-CH(3)-Nic-NHS and 6-CD(3)-Nic-NHS offers a means for the relative quantification of protein by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.
We describe a convenient and useful method for the identification and relative quantification of proteins using light and heavy reagents, 1-(6-methylnicotinoyloxy)succinimides (6-CH(3)-Nic-NHS and 6-CD(3)-Nic-NHS, respectively). This method is based on the chemical derivatization of amino groups of tryptic peptides with these reagents, i.e., the basic moiety of the reagents thus incorporated into both the N-terminal amino group and the epsilon-amino group of the lysine residue would improve the ionization efficiency of tryptic peptides. An increase in protein sequence coverage is achieved by derivatization with these reagents or by combination of mass values before and after derivatization. Since a combination of 6-CH(3)-Nic-NHS and d(3)-labeled reagent (6-CD(3)-Nic-NHS) generates a 3 Da mass difference per reaction site, the d(3)-labeled reagent shifts the mass values of d(0)-labeled peptides according to the number of reactive amino groups in the peptides. In the case of tryptic peptides, the mass values of C-terminal arginine and lysine peptides are shifted by 3 and 6 Da, respectively. Further, the 3 Da mass difference between 6-CH(3)-Nic-NHS and 6-CD(3)-Nic-NHS offers a means for the relative quantification of protein by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.
More Related Videos
07:49Matrix-assisted Laser Desorption/Ionization Time of Flight (MALDI-TOF) Mass Spectrometric Analysis of Intact Proteins Larger than 100 kDa
Published on: September 9, 2013
12:49Quantification of Site-specific Protein Lysine Acetylation and Succinylation Stoichiometry Using Data-independent Acquisition Mass Spectrometry
Published on: April 4, 2018
Related Concept Videos
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Matrix-Assisted Laser Desorption Ionization (MALDI)
MALDI-TOF Mass Spectrometry