Related Experiment Video
Updated: Jul 10, 2026

Screening of Axonal Degeneration in Carpal Tunnel Syndrome Using Ultrasonography and Nerve Conduction Studies
Published on: January 11, 2019
The pneumatic compression test and modified pneumatic compression test in the diagnosis of carpal tunnel syndrome
1Department of Physical Medicine & Rehabilitation, Rheumatology Unite, Faculty of Medicine, University of Yuzuncu Yil, Van, Turkey. iteke58@yahoo.com
Abstract:
There are no precise criteria for the diagnosis of carpal tunnel syndrome (CTS): the history is useful but the value of the various provocative tests is questionable. The purpose of this study was to examine the diagnostic value of a new provocative test, the 'modified pneumatic compression test' in CTS. The study group consisted of 37 patients with 50 symptomatic CTS hands. A control group of 50 healthy volunteers was recruited. The diagnosis was based on a combination of the history, the clinical findings on examination and electrophysiological criteria. Sensitivity for the pneumatic compression and the modified pneumatic compression tests were 68% and 84%, respectively. Specificities for these tests were 97% and 95%, respectively. The modified pneumatic compression test demonstrated high sensitivity and specificity for CTS. This test facilitated the diagnosis and was easy to use. It may reduce referrals for neurophysiology testing, and so reduce costs.
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: